![Hioki MR8740 Instruction Manual Download Page 362](http://html1.mh-extra.com/html/hioki/mr8740/mr8740_instruction-manual_2137324362.webp)
17.6 Input Modules Specifications
350
17.6.2 8967 TEMP Unit
Temperature and humidity
range for guaranteed accuracy
Product warranty period
23 ± 5°C (73.4 ± 9.0°F), 20 to 80% RH (when zero adjustment is executed 30 minutes after power on)
3
year
Period of guaranteed accuracy
1 year
No. of input channels
2 channels
Input terminals
Pushbutton-type terminal block (2 terminals/ch)
Sensor
Thermocouple (K, J, E, T, N, R, S, B, W)
Measurement ranges
Measurable range
Resolution
Measurement accuracy
(f.s.=20 div)
Reference junction compensa-
tion accuracy
± 1.5°C (Reference junction compensation: When internal, add to thermocouple measurement ac-
curacy)
Reference junction compensation
Selectable internal or external (during thermocouple measurement)
Temperature characteristic
Add (meas. accuracy × 0.1)°C to meas. accuracy
Data refresh
Selectable from normal, fast or slow
Open-circuit detection
Selectable On or Off
Input resistance
100M
Ω
(with open-circuit detection Off) or 5.1 M
Ω
± 5% with open-circuit detection On)
Common mode rejection ratio
80 dB minimum (at 50/60 Hz, with signal source 100
Ω
, and Fast data refresh setting)
100 dB minimum (at 50/60Hz, with signal source 100
Ω
, and Normal data refresh setting)
Input type
Unbalanced (floating)
Maximum rated voltage to
earth
300 VAC/DC (between input channels and chassis, and between input channels)
Measurement category II, (anticipated transient overvoltage 2500 V)
Operating temperature and
humidity
Same as the host Memory HiCorder
Storage temperature and humidity
Temperature-20 to 50°C (-4 to 122°F), Humidity 90% RH or less (non-condensating)
Operating environment
Same as the host Memory HiCorder
Dimensions
Approx. 106 mmW × 19.8 mmH × 204.5mmD (4.17"W × 0.78"H × 8.05"D)
Mass
Approx. 240 g (8.8 oz)
Option
Ferrite clamp-on choke........................................................................................ 2
Effect of radiated radio-fre-
quency electromagnetic field
± 2% f.s. (max) at 3 V/m
Effect of conducted radio- fre-
quency electromagnetic field
± 2% f.s. (max) at 3 V
Applicable standards
Safety
EN61010
EMC
EN61326 Class A
Options (sold separately)
Model 9810 Thermocouples (K)
Sensor
Range
Measurable range
Resolu-
tion
Measurement accuracy
Thermocouple
(not including
standard junction
compensation
accuracy)
K
*1
10°C/div
-100°C to 200°C
0.01°C
±0.1% f.s. ± 1°C
± 0.1% f.s. ± 2°C
(-200°C to 0°C)
50°C/div
-200°C to 1000°C
0.05°C
100°C/div
-200°C to 1350°C
0.1°C
J
*1
10°C/div
-100°C to 200°C
0.01°C
50°C/div
-200°C to 1000°C
0.05°C
100°C/div
-200°C to 1100°C
0.1°C
E
*1
10°C/div
-100°C to 200°C
0.01°C
50°C/div
-200°C to 800°C
0.05°C
100°C/div
-200°C to 800°C
0.1°C
T
*1
10°C/div
-100°C to 200°C
0.01°C
50°C/div
-200°C to 400°C
0.05°C
100°C/div
-200°C to 400°C
0.1°C
N
*1
10°C/div
-100°C to 200°C
0.01°C
50°C/div
-200°C to 1000°C
0.05°C
100°C/div
-200°C to 1300°C
0.1°C
R
*1
10°C/div
0°C to 200°C
0.01°C
± 0.1% f.s. ± 3.5°C (0°C to
400°C)
(except B, for which accu-
racy is not guaranteed be-
low 400°C)
± 0.1% f.s. ± 3°C (400°C
and higher)
50°C/div
0°C to 1000°C
0.05°C
100°C/div
0°C to 1700°C
0.1°C
S
*1
10°C/div
0°C to 200°C
0.01°C
50°C/div
0°C to 1000°C
0.05°C
100°C/div
0°C to 1700°C
0.1°C
B
*1
50°C/div
400°C to 1000°C
0.05°C
100°C/div
400°C to 1800°C
0.1°C
W
*2
(WRe5-26)
10°C/div
0°C to 200°C
0.01°C
50°C/div
0°C to 1000°C
0.05°C
100°C/div
0°C to 2000°C
0.1°C
*1: JIS C 1602-1995, *2: ASTM E-988-96
Selection
Fast
Normal
Slow
Data Refresh Rate
1.2 ms
100 ms
500 ms
Summary of Contents for MR8740
Page 2: ......
Page 12: ...Contents x ...
Page 26: ...Operating Precautions 14 ...
Page 128: ...5 5 Miscellaneous Printing Functions 116 ...
Page 196: ...7 12 Setting Output Waveform Parameters 184 ...
Page 234: ...9 5 Numerical Calculation Type and Description 222 ...
Page 248: ...10 3 Waveform Calculation Operators and Results 236 ...
Page 302: ...12 8 FFT Analysis Modes 290 ...
Page 316: ...13 6 Editor Command Details 304 ...
Page 416: ...Appendix 4 FFT Definitions A26 ...
Page 421: ......
Page 422: ......
Page 423: ......
Page 424: ......