Appendix 10 Frequently Asked Questions
A
35
Ap
pe
nd
ix
How can I acquire data contin-
uously starting on April 1,
2015, daily from 9:00 to 17:00,
for one month?
Set as follows:
Measurement Criteria
[Interval]
-
[Cont]
: Off, 8 hr 0 min 0 s
[Repeat]
: On
Timer
[Start]
: On, 15 Year, 4 Mon, 1 Day,
9 Hour 0 Min 0 Sec
[Stop]
: On, 15 Year, 5 Mon, 1 Day,
9 Hour 0 Min 0 Sec
[Interval]
: On, 1 Day, 0 Hour 0 Min
0 Sec
“3.3 Setting Configu-
ration 1 – Recording
Settings” (p.48)
“4.4 Starting and
Stopping Recording
by Timer” (p.92)
Is it possible to measure on 20
channels using two instru-
ments synchronized with each
other?
Measurement start can be synchro-
nized with each others using an ex-
ternal trigger. Sampling cannot be
synchronized with them.
“9.5 Synchronous
Measurements with
Multiple Instruments”
(p.163)
Question
Remedial Action
Reference page
Measuring
Question
Remedial Action
Reference page
What should I do about zero
offset when the input is short-
ed?
Execute zero adjustment to com-
pensate for offset when the inputs
are shorted.
Even though a signal is only in-
put on CH1, why do similar
waveforms appear on unused
channels?
An open-circuit input terminal can be
affected by signals on other chan-
nels. By closing the input terminal
circuit, normal measurement is pos-
sible. If this is impractical, disable
unused measurement channels, or
short the + and - terminals together.
How to display numerical data
values?
Press
WAVE/DATA
repeatedly to
cycle through the Waveform (only),
Wa Numerical Values, and
Numerical Values (only) displays.
Numerical values can be displayed
in a large font on the enlarged nu-
merical display.
Numerical values at specific loca-
tions can be displayed using A/B
cursors.
“1.4 Screen Configu-
rations” (p.20)
“Displaying Cursor
Values” (p.101)
“Viewing Input Sig-
nals as Numerical
Values” (p.104)
What happens to pulse inte-
gration when there are more
than one million pulses?
The counter saturates at
1,073,741,823 counts. If you expect
to exceed this count, we recommend
measuring with the Integration Mode
(
[Count]
) set to Instantaneous
(
[Inst]
), and summing later with a
spreadsheet program.
Summary of Contents for LR8432-20
Page 1: ...EN LR8432 20 HEAT FLOW LOGGER Instruction Manual Jan 2016 Edition 1 LR8432B980 00 16 01H...
Page 2: ......
Page 22: ...Operating Precautions 14...
Page 50: ...2 5 Zero Adjustment 42...
Page 88: ...3 7 Viewing All Channel Settings in a List 80...
Page 104: ...4 5 About Recording Operation 96...
Page 154: ...7 4 Waveform Calculation Formula 146...
Page 164: ...8 3 Making System Settings 156...
Page 232: ...Appendix 12 Heat Flow A44...