![Hioki LR8410-20 Instruction Manual Download Page 105](http://html1.mh-extra.com/html/hioki/lr8410-20/lr8410-20_instruction-manual_2137134105.webp)
3.6 Waveform Display Settings (as needed)
93
3
3
Chapt
er
3 Sett
ings
The vertical display range can be defined by upper and lower limits.
Using this method, the voltage range does not need to be selected because the optimum
range is selected automatically for the display.
Make these settings on the
[CH]
screen.
See:
"Key Setting Procedure" (p .91)
Numerical Value Entry
1. Select a digit to change with the left/right cursor keys, and increment/decrement the digit with
the up/down keys.
(The rightmost character is for an optional measurement unit symbol. Pressing the up/down
keys selects from among E - P - T - G - M - k - (blank) - m - u - n - p - f- a. If no unit symbol is
needed, it can be left "blank".)
2. When the desired value is selected, press
[OK]
.
Magnification and zero-position settings are ignored when the display
range is defined by upper and lower limits.
Specifying the Vertical Display Range by Upper and Lower
Limits (expansion/compression)
• However, upper and lower limit settings are ignored when magnifica-
tion and zero position are enabled to define the display range.
• The range is not automatically optimized when the upper and lower
limits are set on the Waveform/Numerical screen.
10
-10
0
5
-5
0
1
Select
[Up/Lwr]
.
2
Specify the
[Upper]
value for the top of the
display.
Move the cursor to the numerical value and press
EN-
TER
to display the numerical setting dialog.
See:
Numerical Value Entry (below)
3
Specify the
[Lower]
value for the bottom of the
display.
Set in the same way as the upper value.
The display range and scaling settings are interlinked.
1
2
3
Default Setting
Input type
Upper/Lower Limits
Input type
Upper/Lower Limits
Voltage
-0.005 to 0.005
Humidity (Humid)
0 to 100
Temperature (Tc)
0 to 100
Resistance (Resist)
0 to 10
Temperature (Rtd)
0 to 100
Integration (Count)
0
to 5000
Rotation
0
to
5000
Logic
-
Current
0 to 1
Temperature
0 to 100
Fungal index
0 to
200
Fungal growth projection
0 to 4
Increment/decrement by 1
, change sign (+/-)
Select another digit
Numerical Setting Dialog
Summary of Contents for LR8410-20
Page 1: ......
Page 2: ......
Page 12: ...Contents x...
Page 32: ...Operating Precautions 20...
Page 78: ...2 7 Compensating for Input Circuit Offset Zero Adjustment 66...
Page 122: ...3 10 Viewing and Editing with the All Channel Settings List 110...
Page 138: ...4 3 Marking Waveforms and Searching Marks Search Function 126...
Page 222: ...9 4 Synchronous Measurements with Multiple instruments 210...
Page 316: ...13 3 Disposing of the instrument 304...
Page 360: ...Index Index 4...
Page 361: ......
Page 362: ......
Page 363: ......
Page 364: ......