3.3 Input Channel Settings
56
Unit Switching
(Analog input channel settings) UNIT1
UNIT4
→
(pulse input and alarm output chan-
nel settings) PLS & ALM
→
(numerical calculation channel settings) CALC1
→
CALC2
→
and return to UNIT1
Channel Switching
(Analog input channel settings) 1-1
1-15
→
2-1
2-15
→
3-1
3-15
→
4-1
4-15
→
(pulse input and alarm output channel settings) P1
P8
→
ALM1
ALM4
→
(waveform calculation channel settings) W1
W30
→
and return to 1-1
View input status and the display range while making settings on the
[CH]
screen.
After setting, press
MONIT
to confirm input status and display ranges (p. 28).
Monitor display switching
(Right column)
[All Wave]
Displays all channel level monitors.
[UnitWave]
Displays level monitors for all channels in
the selected input unit.
(Left column)
[All Ch]
When
[All Wave]
is selected, displays all
channel level monitors.
When
[UnitWave]
is selected, displays
level monitors for all channels in the se-
lected input unit.
[SlctCh]
Displays a channel level monitor for the
selected channel.
[Value]
Displays numerical values for all channels
in the selected input unit.
Level Monitor
Except when
[Value]
is selected, the gauge is
displayed for the currently selected channels.
The gauge scale is determined by measure-
ment and display range settings.
Monitoring is not available for disabled
(Measurement Off) channels, and those
with
[X]
selected for their color.
Level monitor numerical value refresh rate and waveform horizontal axis span
depend on the recording interval and horizontal axis (time base) settings.
Therefore, long recording intervals can delay numerical value display
refresh by as much as 20 seconds. If you need faster value display
refresh, select a shorter recording interval.
If the horizontal axis (time span) is too long, one division of the waveform
may not be displayed.
Summary of Contents for LR8400-20
Page 1: ......
Page 2: ......
Page 4: ......
Page 26: ...Operating Precautions 14...
Page 96: ...3 9 Viewing and Editing with the All Channel Settings List 84...
Page 112: ...4 3 Marking Waveforms and Searching Marks Search Function 100...
Page 156: ...6 5 Transferring Data to a PC USB Drive Mode 144...
Page 238: ...10 8 About Communications Commands 226...
Page 256: ...11 3 LR8501 Universal Unit Specifications 244...
Page 262: ...12 3 Disposing of the HiLogger 250...
Page 296: ...Index Index 4...
Page 297: ......
Page 298: ......
Page 299: ......
Page 300: ......