![Hioki CM4371-50 Instruction Manual Download Page 71](http://html1.mh-extra.com/html/hioki/cm4371-50/cm4371-50_instruction-manual_2137263071.webp)
65
Input Specifications, Measurement Specifications
Frequency detection
input level
CM4371
-50
20.00 A range
4.00 A or more*
3
600.0 A range
20.0 A or more
CM4373
-50
600.0 A range
40.0 A or more
2000 A range
200 A or more
CM4375
-50
1000 A range
5.0 A or more*
4
Inrush trigger level
CM4371
-50
20.00 A range
+2.0 A or more
Otherwise, −2.0 A or less
600.0 A range
+10 A or more
Otherwise, −10 A or less
CM4373
-50
600.0 A range
+10 A or more
Otherwise, −10 A or less
2000 A range
+100 A or more
Otherwise, −100 A or less
CM4375
-50
1000 A range
+10 A or more
Otherwise, −10 A or less
Peak detection time
width
1 ms or more (with filter disabled)
*1: Does not apply to AC detection in Auto A mode.
*2: Does not include range switching time.
*3: 8.00 A or more for 1 Hz ≤ f ≤ 5 Hz
*4: 10.0 A or more for 1 Hz ≤ f ≤ 5 Hz
HIOKI CM4371C961-00