4.2 Setting Measurement Configuration
61
4
Chapt
er 4
X-Y Recor
der Funct
ion
To set various measurement parameters, press the
STATUS
key to bring up the Status screen and
select the
[Status]
sheet. (Settings for measurement function and sampling rate can also be made
on the Waveform screen.)
Description of setting items ______________________________________
Function
Set the measurement function to X-Y recorder.
Sampling
Select the sampling rate.
Format
Select the graph format for Waveform screen display or printout of the input sig-
nal. Up to 8 phenomena can be observed simultaneously.
Dots-Line
(interpolation)
Determines whether to display and print the input waveform (sampling data) as
dots (sampling points) or perform linear interpolation. The dot display allows
faster sampling.
Disp Clear
If past waveforms remain at the start of measurement, you can either clear or
keep them. If you keep them, the new waveforms will be displayed as an over-
lay.
This completes the measurement configuration settings.
Next, make analog channel settings.
For details, see "3.5.2 Analog Channel" (
4.2
Setting Measurement Configuration
1 ms / 10 ms / 100 ms (default setting)
[1 ms]
can be selected only when
[Dots]
is selected for
[Dots-Line]
item.
X-Y Single
Waveform graphs from 1 up to 8 are displayed and recorded on one
screen. (default setting)
X-Y Quad
Waveform graphs from 1 up to 8 are displayed and recorded on four
screens.
Dots
Display and print sampling data as dots.
Line
Display and print sampling data using linear interpolation.(default set-
ting)
Off
Overlay on existing waveforms
On
Clear existing waveforms(default setting)
To set the channels for X-Y synthesis
See:
Summary of Contents for 8847
Page 1: ...MEMORY HiCORDER Instruction Manual 8847 December 2010 Revised edition 4 8847A981 04 10 12H ...
Page 2: ......
Page 18: ...Operating Precautions 8 ...
Page 26: ...1 4 Basic Key Operations 16 ...
Page 74: ...4 4 Waveform Observation 64 ...
Page 98: ...5 5 Managing Files 88 ...
Page 110: ...6 6 Miscellaneous Printing Functions 100 ...
Page 126: ...7 8 Seeing Block Waveforms 116 ...
Page 160: ...8 10 Making Detailed Settings for Input Modules 150 ...
Page 198: ...10 6 Numerical Calculation Type and Description 188 ...
Page 296: ...15 7 Controlling the Instrument with Command Communications LAN USB 286 ...
Page 304: ...16 2 External I O 294 ...
Page 362: ...Appendix 5 FFT Definitions A28 ...
Page 368: ...Index Index 6 ...
Page 369: ......
Page 370: ......
Page 371: ......