13
1.1 Measuring Battery Wear
索引
4
3
2
1
7
6
5
10
9
8
Ov
e
rvi
ew
The graph below shows the relation between storage capacity
and initial value of internal resistance in a lead-acid battery.
"CS," "HS," and "MSE" denote JIS (Japanese Industrial Stan-
dard) lead-acid battery types.
Internal resistance of an MSE (sealed stationary lead-acid bat-
tery) can be read at approximately 1 m
Ω
(100 Ah) and approxi-
mately 0.13 m
Ω
(1000 Ah). Under conditions of battery wear,
internal resistance rises to 1.5 - 2 times its initial value (refer-
ence values).
Overview
Chapter 1
1.1 Measuring Battery Wear
For determining battery wear, first measure
internal resistance in a new or good battery.
CS : clad stationary lead-
acid battery
HS : high-rate discharge
stationary lead-acid
battery (pasted type)
MSE: sealed stationary lead-
acid battery
Lead-acid battery
[Ah]
[m
Ω
]
In
te
rnal res
is
tanc
e
v
a
lu
e
CS
HS
MSE
Summary of Contents for 3554
Page 1: ...BATTERY HiTESTER INSTRUCTION MANUAL 3554 ...
Page 2: ......
Page 8: ...Contents vi ...
Page 20: ...12 ...
Page 80: ...5 5 Deleting Saved Data 72 ...
Page 116: ...7 4 Using the Software 108 3 Click New File Edit Comparator Table will appear Click ...
Page 132: ...7 4 Using the Software 124 ...
Page 165: ......
Page 166: ......