3.4 Connecting Alarm Output
The terminal blocks use M3.0 screws (at a tighten-
ing torque of 0.5 N•m).
We recommend that you use a round crimp con-
nector (RAV 1.25-3) for connection.
Open collector output (Rating: 30 VDC, 20 mA
max.)
3.4 Connecting Alarm Output
Design the wiring to prevent short-circuiting
of the ALARM and CLAMP SENSOR INPUT
terminals, thus avoiding electric shock and
accidents due to short-circuiting.
• The ALARM terminals are electrically insulated
from the U INPUT terminals and CLAMP
SENSOR INPUT terminals.
• To avoid the effects of external noise, design the
wiring so that cables connected to the ALARM
terminals are separated from those for
measurement, as well as cables connected to
the CLAMP SENSOR INPUT terminals and
voltage cables.