3.3 Connecting the Voltage Cable to the Module
28
1.
Use the U RANGE switch to select 100 V (70 to
130 VAC) or 200 V (140 to 260 VAC).
2.
Connect voltage cables to the U INPUT terminals
(at a tightening torque of 0.8 N•m).
❖
The terminal blocks use M3.5 screws. For connec-
tion, a round crimp connector (RAV 1.25-3.5) is
recommended.
For wiring, cables equivalent to or better than 600
V vinyl-insulated 0.9 mm
2
is recommened.
3.3 Connecting the Voltage Cable to
the Module
Summary of Contents for 2331-20
Page 1: ...INSTRUCTION MANUAL POWER METER 2331 20 MODULE ...
Page 2: ......
Page 26: ...1 4 Dimension Diagrams 22 ...
Page 28: ...2 1 Setting the Module ID 24 ...
Page 44: ...4 2 Insulation of Internal Circuit 40 ...
Page 54: ...5 3 General Specifications 50 ...
Page 56: ...6 2 Service 52 ...
Page 57: ......
Page 58: ......