EXHAUST (J05E)
11–126
REPLACEMENT
EN01F02127100402045002
REMOVING THE EXHAUST BRAKE MAGNETIC
VALVE
1.
DISCONNECTING THE HOSE
(1)
Unfasten the 2 clamps to disconnect 2 hoses from the exhaust
brake magnetic valve.
! CAUTION
Before disconnecting the hoses, put alignment marks.
2.
DISCONNECTING THE HARNESS
(1)
Disconnect the connector from the exhaust brake magnetic valve.
3.
REMOVING THE EXHAUST BRAKE MAGNETIC VALVE
(1)
Unfasten the bolts (2 pcs.) to remove the exhaust brake magnetic
valve from the bracket.
SINGLE UNIT INSPECTION
1.
RESISTANCE TEST BETWEEN TERMINALS
(1)
Use the circuit tester, measure the resistance between the
exhaust brake magnetic valve terminals. Replace if the measure-
ment reading exceeds the standard value.
2.
VENTILATION TEST
(1)
Apply a battery voltage (12 V) between the exhaust brake mag-
netic valve terminals and inspect ventilation.
ÅØÈÁÕÓÔ ÂÒÁËÅ
ÍÁÇÎÅÔÉÃ ÖÁÌÖÅ
SHTS021271000219
SHTS021271000220
Standard value
(20°C {68°F})
10.9 - 16.9
#
$
SHTS021271000221
Inspection conditions
Ventilation
Energized
With ventilation between
A and B