EXHAUST (J05E)
11–61
REPLACEMENT
EN01F02127100402054002
REPLACING THE FILTER
1.
CAUTIONS
! CAUTION
After-run (DEF drawn back to the DEF tank) is performed after the
starter key is turned to “LOCK” and the muffler temperature
drops. Before starting work, wait for at least 10 minutes after turn-
ing the starter key to “LOCK.”
2.
REMOVING THE FILTER
(1)
Turn the filter cover counterclockwise using the 27 mm {1.06 in.}
box (dodecagon) to remove it from the DEF pump.
! CAUTION
Prepare the reservoir and waste to collect dripping DEF when
removing the fuel cover.
(2)
Remove the filter and equalizer from the DEF pump.
DEF PUMP
FILTER COVER
SHTS021271000092
DEF PUMP
FILTER
EQUALIZER
SHTS021271000093