TITLE
DC MOTOR REMOVAL AND REPLACEMENT
WARNING: Disconnect Vehicle Battery
prior to performing this procedure to
avoid electrical shock or burns.
1
2
PHOTO NO. 8996A
Disconnect the black wire of the battery power
cable at location 2. Disconnect the red (or red
striped) wire of the battery power cable from the
motor terminal at location 1.
MOUNT BOLTS
PHILLIPS HEAD SCREWS
MOTOR CAP
MOTOR
DWG NO. 3512
Remove the two Phillips head screws from the
motor cap. Using a 3/8” wrench loosen the two
motor mounting bolts. Do not remove bolts.
NOTE:
Use care when removing the motor from
the endhead, the motor can separate into three
pieces and will require additional time to reas-
semble.
Hold motor together while removing it from the
end head.
NOTE:
If oil is found in the cavity of the valve
passage where the coupling is located, replace-
ment of the oil pump shaft seal is necessary be-
fore the unit can be put back into service. See
page 23.
PHILLIPS HEAD SCREWS
MOTOR CAP
MOTOR
MOTOR TERMINAL
(POS)
GROUND SCREW
(NEG)
COUPLING
PUMP SHAFT
VALVE PASSAGE
SHIPPING NUTS
(REMOVE)
DWG NO. 3513
Remove shipping nuts from new motor, align
splined shaft of motor with coupler and position
motor onto the locating pins on the end head.
Torque the two motor mounting bolts to 5-8 ft.
lbs. with a 3/8” wrench. Reattach motor cap.
Reconnect the black wire of the battery power
cable at location 2 and the red (or red striped)
wire of the battery power cable to motor termi-
nal at location 1. See photo 8996A.
DC Motor Removal and Replacement 13