background image

DX 460 SM

Operating instructions

en

Mode d’emploi

fr

Manual de instrucciones

es

Инструкция по зксплуатации

ru

Printed: 08.07.2013 | Doc-Nr: PUB / 5129667 / 000 / 01

Summary of Contents for DX 460 SM

Page 1: ...DX 460 SM Operating instructions en Mode d emploi fr Manual de instrucciones es Инструкция по зксплуатации ru Printed 08 07 2013 Doc Nr PUB 5129667 000 01 ...

Page 2: ...1 3 5 4 6 11 12 1 2 9 10 7 8 DX 460 13 MX SM 14 Printed 08 07 2013 Doc Nr PUB 5129667 000 01 ...

Page 3: ... 8 3 2 M X SM DX 460 DX 460 5 4 MX SM DX 460 X SM DX 460 DX 46 0 DX 46 0 MX SM DX 46 0 DX 46 0 MX SM DX 46 0 DX 46 0 MX SM MX SM DX 460 6 MX SM MX SM 6 3 1 4 5 6 7 1 7 8 1 2 3 4 5 6 7 1 Printed 08 07 2013 Doc Nr PUB 5129667 000 01 ...

Page 4: ... 7 6 MX SM D X 4 6 0 D X 4 6 0 MX SM DX 460 DX 750 DX 650 min max Steel base material Untergrund Stahl MX SM DX 460 X SM DX 460 CLICK MX SM MX SM MX SM 2 3 7 2 8 3 8 4 1 2 3 4 5 8 9 7 4 1 10 11 7 6 5 4 1 MX SM DX 460 DX 460 2 3 5 6 Printed 08 07 2013 Doc Nr PUB 5129667 000 01 ...

Page 5: ...er which may explo de and cause severe injuries to operators and bystan ders At a minimum cartridges must either a Be confirmed by their supplier for successful testing according to EU standard EN 16264 NOTE All Hilti cartridges for powder actuated tools have been tested successfully in accordance with EN 16264 The tests defined in the EN 16264 standard are system tests carried out by the certific...

Page 6: ...ch a way that it can be neither reused nor misused Never attempt to pry a cartridge from the magazine strip or the tool Keep the arms flexed when the tool is fired do not straighten the arms Never leave the loaded tool unattended Always unload the tool before beginning cleaning servicing or changing parts and before storage Store cartridges and unused tools unloaded in a dry high or locked place o...

Page 7: ... reduced veloc ity less than 100 m sec in a controlled manner The driving process ends when the piston reaches the end of its travel This makes dangerous through shots vir tually impossible when the tool is used correctly The drop firing safety device is the result of coupling the firing mechanism with the cocking movement This prevents the Hilti DX tool from firing when it is dropped onto a hard ...

Page 8: ...8mm 1 4 6 4mm 3 8 9 5mm 5 16 8mm Due to variations in site conditions site testing required Note Refer to the nail cartridge selector chart for more detail information Contact your local Hilti marketing organiza tion for technical support with diaphragm design calculations and project submittals Fastener program For approval relevant roof and floor decking applications SDI ICBO FM UL approved Arti...

Page 9: ... 22 C B A Steel A min edge distance 10 mm 3 8 B min spacing 20 mm 3 4 C min base material thickness 3 2 mm 1 8 Piston Article no Ordering designation Application description 373303 X 460 PSM Standard piston for HSN and FDN pins Accessory Article no Ordering designation Application description 373330 X 460 B Buffer does not fit the DX A41 SM tool 370831 X SH 460 Standup handle for DX 460 SM Cleanin...

Page 10: ...y press the XM SM fastener magazine on the gas return unit of the tool 9 Fully screw the magazine on the tool until it clicks into place Note The MXSM fastener magazine must only be used with a DX460 tool 6 3 Fitting the DX460SM to the standup handle X SH460 1 Ensure that there is no cartridge strip in the tool If there is a cartridge strip in the tool remove it by hand from the tool 2 Unscrew the...

Page 11: ...sing the unlock power regulator key 7 Turn the power regulator wheel 1 minimum power 4 maximum power Note Start with minimum power If the fastener does not penetrate deep enough increase the driving pow er 8 Use the supplied nail standoff template to check the correct penetration depth 9 When fastening position the tool at right angles to the working surface press down and then pull the trigger No...

Page 12: ...y using the supplied ram rod 5 Check the buffer and the piston for wear Replace the buffer X 460B by bending it to separate it from the magazine if the metal ring is loose or broken it stays no longer on the magazine interface excessive uneven wear under the metal ring Replace the piston X 460 PSM if it shows signs of wear it is broken it has cracks the tip is heavily worn e g a 90 degree segment ...

Page 13: ...gments could be blocking the nail detection mechanism The piston sticks in the piston guide and cannot be Unscrew the exhaust gas piston return unit pulled out see major service point 8 4 Push out the piston through the cartridge chamber using the supplied ramrod The piston could be jammed by rubber buffer fragments or excessive dirt Debris becomes stuck in the fastener guide Pull the cartridge st...

Page 14: ...ridge strip one cartridge If the problem occurs more often Clean the tool If the problem persists Contact Hilti Center Tool is compressed too long while fastening Fastening frequency is too high Compress the tool a shorter time while fastening Remove the cartridge strip Disassemble the gas return unit see 8 4 for fast cooling and to avoid possible damage If the tool cannot be disassembled Contact ...

Page 15: ...hich Hilti power actuated tools are manufactured can be recycled The materials must be correctly separated before they can be recycled In many countries Hilti has already made arrange ments for taking back your old powder actuated tools for recycling Please ask your Hilti customer service department or Hilti sales representative for further information Should you wish to return the power actuated ...

Page 16: ...ng organization provided This constitutes Hilti s entire obligation with regard to warranty and supersedes all prior or contemporaneous comments and oral or written agreements concerning warranties 13 CIPapprovalmark The following applies to C I P member states outside the EU and EFTA judicial area The Hilti DX 460 has been system and type tested As a result the tool bears the square approval mark...

Page 17: ...895 1 in the semi anechoic test room of Mu ller BBM GmbH The ambient conditions in the test room conform to DIN EN ISO 3745 Testing procedure Enveloping surface method in anechoic room on reflective surface area in accordance with E DIN EN 15895 DIN EN ISO 3745 and DIN EN ISO 11201 NOTE The noise emissions measured and the associated measurement uncertainty represent the upper limit for the noise ...

Page 18: ...14 Printed 08 07 2013 Doc Nr PUB 5129667 000 01 ...

Page 19: ...423 2342111 Fax 423 2342965 www hilti com Hilti registered trademark of Hilti Corp Schaan W 2713 0713 10 Pos 3 1 Printed in Liechtenstein 2013 Right of technical and programme changes reserved S E O 371686 A3 Printed 08 07 2013 Doc Nr PUB 5129667 000 01 ...

Reviews: