Host Interface
40/64
COM-C | Communication Module
DOC021001DG12EN | Revision 12 | English | 2011-06 | Released | Public
© Hilscher, 2002-2011
3.3.6
Fieldbus Connector X2 for CC-Link-Slave
Fieldbus connector X2 for COM-CN-CCS
Pin
Signal
Symbol
Type
Pin at Fieldbus
Connector
COMBICON
5pin
1
2
Receive Driver Enable
RDENL#
8 mA Output
Note 1
3
4
CC-Link, Transmission period signal
SDGATEON
12 mA Output
Note 1
5
6
CC-Link, Transmission Data
SD
4 mA Output
Note 1
7
8
CC-Link, Received Data (channel 1)
RD1
TTL Input
Note 1
9
10
11
12
13
COM-LED, STA, Cathode yellow LED
STA#
4 mA Output
14
SYS-LED, RUN, Cathode green LED
RUN#
4 mA Output
15
COM-LED, ERR, Cathode red LED
ERR#
4 mA Output
16
SYS-LED, RDY, Cathode yellow LED
RDY#
4 mA Output
17 Ground
GND
18 Power
Supply
+3.3V
19
20
Don't use - needed for isolation
21
Don't use - needed for isolation
22
23
24
25
26
CC-Link, Data A
DA
1
27
CC-Link, Data B
DB
2
28
CC-Link, Data Ground
DG
3
29
CC-Link, Function Ground
FG
5
30 CC-Link,
Shield
SLD
4
Table 22: Fieldbus Connector X2 for CC-Link-Slave
Note
Information
1
Signals could be only used without the hardware interface on the COM. Ask for a special customer version.
Table 23: Notes for Fieldbus Connector X2 for CC-Link-Slave