Technical Data
214/299
PC Cards cifX Compact PCI, Mini PCI, Mini PCIe, PCI-104 | Installation, Operation and Hardware Description
DOC120205UM53EN | Revision 53 | English | 2019-03 | Released | Public
© Hilscher, 2008-2019
CIFX 104C-RE\F,
CIFX 104C-RE-R\F
and Variants
Parameter
Value
EN 61000-4-3:2006 + A1:2008 + A2:2010 (Radiated,
radio-frequency, electromagnetic field test)
EN 61000-4-4:2004 + A1:2010 (Burst Electrical fast
transients/burst test)
EN 61000-4-5:2006 (Surge test)
EN 61000-4-6:2009 (to conducted disturbances, induced
by radio- frequency fields)
EN 61000-4-8:2010 (power frequency magnetic field test)
EN 61000-6-2:2005 + B1:2011 (for industrial
environments)
UL Certification
The devices CIFX 104C-RE\F
and CIFX 104C-RE-R\F are
certified according to UL 508
UL-File-Nr. E221530
Configuration Software
Master and Slave
SYCON.net
Configuration
Configuration Software Slave
netX Configuration Tool
Table 152: Technical Data CIFX 104C-RE\F, CIFX 104C-RE-R\F, CIFX 104C-RE\F\M12 or
CIFX 104C-RE-R\F\M12
10.1.23 CIFX 104C-DP, CIFX 104C-DP-R
CIFX 104C-DP,
CIFX 104C-DP-R
Parameter
Value
CIFX 104C-DP
1270.410
Name, Part No.
CIFX 104C-DP-R
1271.410
Description
PC Card cifX PCI-104 PROFIBUS DP Master or Slave and
PROFIBUS MPI Device;
(for CIFX 104C-DP-R connectors at the left side)
Part
Function
Communication Interface with PCI-104 and fieldbus
interface PROFIBUS
Communication
Controller
Type netX
100
processor
RAM
8 MB SDRAM
FLASH
4 MB serial Flash EPROM
Integrated Memory
Size of the Dual-Port Memory
64 KByte
Bus Type
PCI-104, according to [bus spec 7], refer to section
Transmission Rate
33 MHz
Data Access
DPM or DMA (Direct Memory Access)
System Interface
Width for the data access to the
Dual-Port Memory (DPM)
32-Bit
PROFIBUS
Communication
Supported communication
standard/ protocol (determined by
the loaded firmware)
PROFIBUS DP Master,
PROFIBUS DP Slave,
PROFIBUS MPI Device
Transmission Rate
9,6 kBit/s, 19,2 kBit/s, 31,25 kBit/s, 45,45 kBit/s,
93,75 kBit/s, 187,5 kBit/s, 500 kBit/s, 1,5 MBit/s,
3 MBit/s, 6 MBit/s, 12 MBit/s
Interface Type
RS 485, refer to section
, page 154.
Galvanic Isolation
isolated
Isolation Voltage
1000 VDC (tested for 1 minute)
PROFIBUS Interface
Connector
DSub female Connector, 9 pin