Device Connections and Switches
152/299
PC Cards cifX Compact PCI, Mini PCI, Mini PCIe, PCI-104 | Installation, Operation and Hardware Description
DOC120205UM53EN | Revision 53 | English | 2019-03 | Released | Public
© Hilscher, 2008-2019
9.1.2
Ethernet Pin Assignment at the M12 Socket
Real-Time Ethernet 2 x M12 plug connections (to DIN EN 61076 2 101/ IEC
61076 2 101), D-coded socket.
Note:
The device supports the
Auto Crossover
function. Due to this fact
RX and TX can be switched. The following figure shows the M12 standard
pin assignment.
Figure 62: Ethernet Pin Assignment at M12 Socket for AIFX-RE\M12 (D coded)
Pin
Signal
Meaning
1
TX+
Transmit Data +
2
RX+
Receive Data +
3
TX–
Transmit Data –
4 RX– Receive
Data
–
PE
Metal screw connection
Table 107: Ethernet Pin Assignment M12 Socket for AIFX-RE\M12
Note:
With loaded EtherCAT Master firmware only the M12 channel 0 can
be used, channel 1 is deactivated. Beginning with the EtherCAT Master
firmware version 3 channel 1 can be reactivated if redundancy is
activated. For the Open Modbus/TCP firmware with V2.3.4.0 and higher
both M12 channels can be used.