Technical Data
134/223
PC Cards cifX PCI, PCIe, Low Profile PCIe | Installation, Operation and Hardware Description
DOC120204UM46EN | Revision 46 | English | 2015-12 | Relelased | Public
© Hilscher, 2008-2015
CIFX 50-2DP\CO
Parameter
Value
Operating temperature range*
-20 °C ... +70°C
*Air flow during measurment
0,5m/s
Storage temperature range
-10 °C ... +70 °C
Environmental
Conditions
Humidity
10 … 95% relative humidity, no condensation permitted
Dimensions (L x W x H)
120 x 94,5 x 18,5 mm
Mounting/Installation
PCI slot (3.3 V), refer to section
Slot for the PC Cards cifX
PCI, PCIe and Low Profile PCIe
, page 33.
Device
RoHS Yes
CE Sign
Yes
Emission
EN 55011:2009 + A1:2010, CISPR 11:2009, Class A
(Radio disturbance characteristics - Limits and methods of
measurement)
CE Sign
Immunity
EN 61000-4-2:2009 (Electrostatic discharge test)
EN 61000-4-3:2006 + A1:2008 + A2:2010 (Radiated,
radio-frequency, electromagnetic field test)
EN 61000-4-4:2004 + A1:2010 (Burst Electrical fast
transients/burst test)
EN 61000-4-5:2006 (Surge test)
EN 61000-4-6:2009 (to conducted disturbances, induced
by radio- frequency fields)
EN 61000-4-8:2010 (power frequency magnetic field test)
EN 61000-6-2:2005 + B1:2011 (for industrial
environments)
Configuration Configuration
Software Master
SYCON.net
Table 106: Technical Data CIFX 50-2DP\CO
10.1.13 CIFX 50-2DP\DN
CIFX 50-2DP\DN
Parameter
Value
Name CIFX
50-2DP\DN
Part No.
1252.480
Description
PC Card cifX PCI 2 channel -
Channel X0: PROFIBUS DP Master or Slave,
Channel X1: DeviceNet Master or Slave
Part
Function
Communication interface with PCI, 1 x PROFIBUS and
1 x DeviceNet interface
Communication
Controller
Type netX
100
processor
RAM
8 MB SDRAM
FLASH
4 MB serial Flash EPROM
Integrated Memory
Size of the Dual-Port Memory
64 KByte
Bus Type
PCI, according to [bus spec 1], refer to section
Overview
,
page 114.
Transmission Rate
33 MHz
Data Access
DPM or DMA (Direct Memory Access)
System Interface
Width for the data access to the
Dual-Port Memory (DPM)
32-Bit
PROFIBUS
Communication
Supported communication
standard/ protocol (determined by
the loaded firmware)
PROFIBUS DP Master,
PROFIBUS DP Slave
PROFIBUS Interface
Transmission rate
9,6 kBit/s, 19,2 kBit/s, 31,25 kBit/s, 45,45 kBit/s, 93,75
kBit/s, 187,5 kBit/s, 500 kBit/s, 1,5 MBit/s, 3 MBit/s,