49
Chapter 3 Installation
|
Hillstone
Hillstone SG-6000 X-Series Hardware Reference Guide
Installing an SSM
The device requires at least one SSM and it supports up to 10 SSMs. SSM is located in
Slot1 to Slot10.
The following section takes SSM-20 as an example to describe the installation of SSM.
To install an SSM, take the following steps:
1.
Wear an electrostatic discharge (ESD) strap around your bare wrist and connect
the strap to an ESD point on the chassis. See
2.
Take the SSM out of its antistatic bag.
3.
Identify the slot of SSM.
4.
If the slot is covered with a blank plate, loose its screws with a cross
screwdriver and remove the plate.
5.
Position the SSM so that its front side faces you, and slide the SSM into the slot
until you feel resistant, as shown below.
Figure 3-11: Installing an SSM (SSM-20)
6.
Tighten the screws on the SSM with a cross screwdriver.
7.
To install more SSMs, repeat Step 2 to 6.
Note:
The tray is installed in each expansion slot at the factory, and you can install the
half width modules by taking the above steps. When installing the full width modules
(such as SSM-200, QSM-200, IOM- -200, IOM- and IOM-8SFP+),
you should remove the tray and install the modules by taking the above steps.
Installing a QSM
QSM is specially used to process QoS services. QSM is located in Slot1 to Slot10.
The following section takes QSM-20 as an example to describe the installation of QSM.
To install a QSM, take the following steps: