Installing Expansion Modules of SG-6000-X8180
The device requires at least one SCM-260/SCM-D1T-260/SCM-D2T-260 and one SIOM-P100-
260. Additional expansion modules are added according to your needs.
This part includes the following sections:
l
l
l
Tools Required
The following tools are required to install an expansion module:
l
Cross screwdriver
l
ESD wrist strap
Installing an SCM
SG-6000-X8180 supports up to two SCMs. SCM is located in the slot SCM0 and SCM1 of the
back panel.
To install an SCM, take the following steps:
1. Make sure the SCM expansion module will not be powered during the installation process.
2. Wear an electrostatic discharge (ESD) strap around your bare wrist and connect the strap to
an ESD point on the chassis. See
.
3. Take the SCM module out from its antistatic bag.
4. Face the back panel of the chassis, and identify the slot in which the module should be
installed.