Replacing an SIOM
To replace an SIOM, take the following steps:
1. Wear an electrostatic discharge (ESD) strap around your bare wrist and connect the strap to
an ESD point on the chassis. See
.
2. Use a cross screwdriver to loosen SIOM screws until they pop out.
3. Rotate the lever to outside till the lever head is out of the expansion slot.
4. Hold the module with one hand and pull it straight out of the expansion slot along the guide
rail.
5. Put the removed module into an antistatic bag or on a flat antistatic table.
6. Install a replacement module (see
).
Notes: If you do not want to install a new module, apply a blank plate over the slot
to avoid dust falling into the chassis.
Chapter 5 Hardware Maintenance and
Replacement
136
Summary of Contents for SG-6000 X Series
Page 1: ...Hillstone SG 6000 X Series Hardware Reference Guide TechDocs docs hillstonenet com...
Page 11: ...Troubleshooting the Configuration System 156 Appendix Supported Versions of Devices 158 TOC 9...
Page 40: ...SSM 100 SSM 80 is shown as below SSM 20 is shown as below 28 Chapter 1 Product Profile...
Page 45: ...IOM 16SFP 100 is shown as below IOM 4XFP 100 is shown as below Chapter 1 Product Profile 33...
Page 48: ...SIOM P100 300 is shown as below SIOM P100 260 is shown as below 36 Chapter 1 Product Profile...
Page 80: ...Chapter 2 Installation Preparations 68...
Page 83: ...71 Chapter 2 Installation Preparations...
Page 84: ...Chapter 2 Installation Preparations 72...