Photocell beam sensor and flash lamp User Manual  (PF5103)

1. Working voltage: 12~24VAC/DC
2. Working current(24VDC):emitter: 

15mA    receiver: 

30mA

3. Photocell wavelength: 940nm
4. Angle of opposite emission: 

±5°

5. Receiver range: 

12m

6. Working temperature: -20

℃~

+60

7. Relay contact loading capacity: 1A/30VDC
8. Waterproof grade: IP54
9. Can connect external flash lamp signal (12V-24VAC/DC), LED can flashing.
10. Size: 127*50*35mm
11. Weight: 150g

I. Technical Specification

II. Safety Instruction

1. For security, please read the user manual carefully before initial operation;
2. This photocell is without any fuse, so Please make sure the power is off before installation;
3. This product is only used for the equipment which will not cause life or property hazards when a breakdown happens or its
security risks have been already eliminated;
4. Please guarantee the products used in effective working range.

III. Picture Display

IV. Installation instruction

1. The product should be installed more than 20cm upper the ground(to avoid reflection), and the distance between emitter and
receiver shall be more than 0.5 meters(if not , maybe the photocell will working on or cannot work);
2. the end user  should installed the photocell on the back of the direct sunshine or other strong shining(±5º) to keep the photocell
work well steadily.
3. Pls try to avoid installing other photocell emitters within effective receive range;
4. If install many photo cells on the same line, can install receivers on two ends and then emitters in the middle back to back which
can effectively avoid the  problem as above.
5. In order to avoid signal bias of emitters and receivers which will easily cause mis-operation, pls Installate the photocell firmly
6. Connecting power after checking no error of connecting lines:
6.1 Photocell
6.1.1 After the emitter and receiver module of photocell input 12V-24VAC/DC, emitter LED on,keep the CAP of emitter and receiver
align, receiver LED off ; When they are not align, receiver LED on.
6.1.2 After the emitter and receiver module of photocell input 12V-24VAC/DC,NO/COM connects while NC/COM disconnects;keep
the CAP of emitter and receiver align, NC/COM connects while NO/COM disconnects;When they are not align,NC/COM disconnects
while NO/COM connects.
6.2 Flash lamp
6.2.1 When there is signal income from FLASH port(12V-24V AC/DC)
It keeps lighting when JP1 CAP connects the two pins under
It blinks  when JP1 CAP connects the two pins upper
6.2.2 When there is no signal income from FLASH port(12V-24V AC/DC)
It doesn't work when JP1 CAP connects any two pins