Technical Specification
1.
Working voltage
:
12-240VAC /DC
2.
Loading capacity
:
<3W
3.
Flicker Frequency
:
1HZ
4.
Working temperature
:
-20º
~
+60
℃
5
.
Size
:
φ86* 125mm
6. Weight: 83g
III.
Connecting Instruction
1.
Port CN1 is for connecting the power input, working voltage is 12-240VAC/DC
2.
Port CN2 is for connecting the antenna to extend the effective distance of controller
IV.
Instructions
4.1
LED will flicker in 1HZ after power on
4.2
JP1 switch
It’s the switch for switching LED in flickering or lighting,
When JP1 at flash, LED will flicker in 1Hz after power on;
When JP1 at No flash, LED will light after power on
Danger: The whole product including the LED is with high voltage when power on (Power off before open the case)
V.
Installation
5.1 F6000 with bracket
2
.
Mark the 2 holes as it in picture
1
.
Open the package ,take out the
accessories
and
rotate
the
antenna anticlockwise.
3
.
Drill two 6mm diameter holes and one 10mm
diameter hole. Then put the expansion tube into 6mm
diameter holes, put wire through 10mm diameter hole.