F5001 A3 Flash lamp user manual Version: A8
F5001 Flash lamp user manual
I.
Technical Specification
1.
working voltage
:
24V AC/DC
2.
Loading capacity
:
less than 16W
3.
Flicker Frequency
:
1HZ
4.
Working temperature
:
-20º
~
+60
℃
5.
IP Level: IP54
6
.
Size
:
φ90* 125mm
7
.
Weight
:
152g
II.
Connecting Instruction
1.
Connect the wire with J1 if power supply is 24V AC/DC
2.
J2 is for connecting the antenna to extend the effective distance of controller
III.
Instructions
4.1
Bulb will flicker in 1HZ after power on
4.2
JP1 switch
It’s the switch for switching bulb in flickering or lighting,
When JP1 at FLASH, bulb will flicker in 1HZ after power on;
When JP1 at NO FLASH, bulb will light after power on
IV.
Installation
1
.
Open the package and take out
the accessories for installation.
2
.
Stick the paper on the proper place, and then drill the hole.