background image

F5001 A3    Flash lamp user manual                                                                                                                                                        Version: A8 

F5001 Flash lamp user manual

 

I.

 

Technical Specification 

1.

 

working voltage

24V AC/DC 

2.

 

Loading capacity

less than 16W 

3.

 

Flicker Frequency

1HZ 

4.

 

Working temperature

-20º

+60

 

5.

 

IP Level: IP54 

6

  Size

φ90* 125mm   

7

  Weight

152g 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

II.

 

Connecting Instruction 

1.

 

Connect the wire with J1 if power supply is 24V AC/DC   

2.

 

J2 is for connecting the antenna to extend the effective distance of controller 
 

III.

 

Instructions 

4.1

 Bulb will flicker in 1HZ after power on

 

4.2 

JP1 switch 
It’s the switch for switching bulb in flickering or lighting, 
When JP1 at FLASH, bulb will flicker in 1HZ after power on; 
When JP1 at NO FLASH, bulb will light after power on 
 

IV.

 

Installation 

 
 
 

 

1

Open the package and take out 

the accessories for installation. 

2

Stick the paper on the proper place, and then drill the hole. 

 