ENGLISH
7
MASTER MANAGER MENU OPTIONS
Entering Master Manager Menu
To enter, press
d
and enter the Master Manager code.
Exiting Master Manager Menu
Press
x
until the keypad displays ‘EXIT MASTER MANAGER MENU?’ then press
t
. Alternatively, press
a
when on a main
menu item (indicated by being displayed in capital letters).
Main Menu Items
MENU ITEM
DESCRIPTION
Bypass Zones
Disables any 24 hour zone.
Operate User PGMs
Activates and deactivates any PGMs programmed as a user automation output.
Date & Time
Used to program the local date and time.
Learn User Codes, Keyfobs & Tags Add/edit and delete users from the system.
Review Log
Used to view all the operational events in chronological order.
Set Up App
Change basic settings and passwords for the smart device application and cloud.
SMS Phonebook
Edit the phone-numbers programmed to receive SMS messages.
Voice Phonebook
Edit the phone-numbers programmed to receive voice messages.
Walk Test
A function to test all the active zones on the system.
Siren Test
Tests all PGMs programmed as external siren output.
Allow Engineer Menu
Allows and blocks access to the Engineer Menu.
Check Credit
Checks the credit on a SIM card.
Block Remote Arming
Blocks any attempt to arm the system remotely via upload/download software.
Block UDL
Blocks any attempt to connect to the control panel with any programming software.
ADDING & EDITING USERS
1. Enter the Master Manager Menu.
2. Press
x
until the LCD shows ‘LEARN USER CODES, KEYFOBS & TAGS?’ then press
t
.
3. Press
t
to add or edit standard users or
x
to edit Master Manager code
Adding a New User
1. Use
[
and
]
to select an empty user and press
t
.
2. Enter new code, present proximity fob or press the lock button on the keyfob, press
t
.
3. Using
[
and
]
, select whether this code is to be used as a user or a manager and press
t
.
4. Select the areas that the code is permitted to arm and disarm then press
t
.
5. Using
[
and
]
, select whether this code can arm and disarm, arm or disarm only or none then press
t
.
6. Area arm choice enables the user to choose which areas to arm and disarm. Press
]
to enable this option, then press
t
.
7. Enter a username and then press
t
to finish.
Please note: If a keyfob is being added, after it has been learnt to a user the options will be different from those shown
above. Refer to the online Extended User Guide for more information.
Editing or Deleting a User
1. Use
[
and
]
to select the existing user and press
t
.
2. Press
c
to delete the user or
t
to edit the user.
3. If editing, all the options that were selected when creating the user can now be altered.