background image

E

x

it

M

a

s

te

r

M

a

n

a

g

e

r

M

e

n

u

Press th

a

 k

e

y to e

xi

t Master 

Manager mode from an

y main men

item (displa

y

ed in capital letters)

EXIT MANA

G

ER

MODE?

Enf

orcer

BYP

ASS INPUTS?

Enf

orcer

BYP

ASS INPUT

S?

B

A

OR:

Time          10:09     c

Time

   

   

   

 10:09   

  c

Enforcer User Guide

102017855 - V01

33

Summary of Contents for Pyronix Enforcer 64

Page 1: ...102017855 V01 Software V12 0 Enforcer 64 User Guide...

Page 2: ...formation about using and managing the product after installation and commissioning Conventions This document uses the following conventions For more information A cross reference to a related or more...

Page 3: ...omeControl App 14 HomeControl App Icons 17 Configuration 18 Chime Feature 18 PA from Keypad 18 Fire Alarm from Keypad 18 Master Manager Menu Options 19 Entering the Master Manager Menu 20 Bypass Input...

Page 4: ...Inputs 36 Outputs 37 Users 38 Compliance 39 Notes 40 iv Enforcer User Guide 102017855 V01...

Page 5: ...d unlike other conventional systems High Security Encryption 128 bit high security wireless encryption protocol and intelligent wireless jamming detection User Friendly Keyfobs The two way wireless ke...

Page 6: ...the Enforcer check the system status and bypass inputs It also allows you to activate devices remotely such as gates lights sprinklers and more The HomeControl App and PyronixCloud communication is fu...

Page 7: ...ger fire alarms only if enabled by an engineer Move from one option to another while in a sub menu Move through text t Select items and enter into a sub menu or option 0 Enter a space when entering te...

Page 8: ...d in the Master Menu t Enforcer Enter Your Code Arm Areas Please Wait Arming Wireless Arming 029 Area A Press the A B C or D keys to select the area to be armed User Code User Code Stop Arming t t t T...

Page 9: ...your system 1 Enter your User Code on the keypad The User Code needs to be programmed in the Master Menu t Enforcer Enforcer Enter Your Code Disarm Areas User Code t Press the A B C or D keys to sele...

Page 10: ...icate the system is disarmed The keyfob buttons can be programmed in the Master Manager Menu Learn User Codes Tags Keyfobs Using the Keyfob The wireless keyfob has four buttons that can be programmed...

Page 11: ...b again and the system will arm immediately The disarm LED on the panel will turn off and a beep will sound to signal that the system has been armed The RED LED on the keyfob will illuminate for a sho...

Page 12: ...without the ability to arm or disarm Please contact your installer for more information on this feature If the system fails to arm a faultwilldisplay on the internaltag reader or a failed to arm soun...

Page 13: ...ecure password for the HomeControl App and press t Poll Server is displayed 8 If required choose a Poll Server setting and press t It is recommended that Poll Server is set to Yes For more information...

Page 14: ...Systems and System Polling will be displayed on the right The green tick shows that the system is connected 4 Set up the HomeControl app Setting Up The HomeControl App Adding a Panel to the App 1 Open...

Page 15: ...dem is installed This allows the smartdevice to send SMS to the controlpanelin order to force the modem to pollthe cloud If the panelhas been programmed to pollthe cloud these options are notapplicabl...

Page 16: ...reen below will be displayed 5 To disconnect select X next to Disconnect Allnew smartdevices when firstconnected willbe disabled by default The cloud administrator willneed to manually enable these de...

Page 17: ...Delete Unable to arm area Edit Area cannot be armed Add system Detector fault New notification Area in alarm Notifications Supervision fault Search Output is off or option is set to no Refresh Output...

Page 18: ...n to re enable the chime PA from Keypad If you require a PA Panic Alarm press and hold both the 1 and 7 keys or hold p for 2 seconds by default and a PA alarm will be generated The PA feature and the...

Page 19: ...nebook If SMS is enabled up to 10 mobile numbers can be programmed for the panel to send SMS alarms Please discuss this feature with your installer if required Walk Test The Walk Test function allows...

Page 20: ...1234 We highly recommend that you change this code Enforcer Enter Your Code BYPASS INPUTS D t Time 10 09 c Bypass Inputs Choose an input BYPASS INPUTS Bypass Inputs Bypass Inputs OPERATE USER OUTPUTS...

Page 21: ...tput OPERATE USER OUTPUTS Select Output 01 Output Off Output On DATE TIME B Pressing t alternates between ON OFF then press x when the status desired is shown to set it as that Turn Output On Off 30 O...

Page 22: ...ly when a PSTN modem is installed GPRS is network dependant Options 0 No 1 Yes DATE TIME Year 00 99 Timezone 117 Month 1 12 Day 1 31 Hours 0 23 Summer Time Adj LEARN USER CODES KEYFOBS TAGS B Minutes...

Page 23: ...m Only 2 Arm Only 3 None Area Arm Choice 0 No 1 Yes User Arm Options User Arm Options Area Arm Choice User Name _ User in Area Master Manager Code Change Master Manager Code User Arm Options 0 Disarm...

Page 24: ...utomatically arm all areas the panel code is assigned to User Codes Tags Learn Keyfobs Empty 03 Enter User Code Press C Key to delete code Present tag User Type User in Area User Arm Options 0 Disarm...

Page 25: ...tton Action 0 No Action 1 Show Status 2 Arm Area 3 Disarm Area 4 Operate Output 6 PA Panic Alarm only for 2 button options Select Button 1 Button LOCK 2 Button UNLOCK 3 Button I 4 Button II 5 Buttons...

Page 26: ...ET UP APP Panel Log 01 01 00 11 44 User 01 Repeat for all Events Start of Log To obtain more information on the event Press c Access Ctrl Log 01 01 00 11 44 User 01 Repeat for all Events Start of Log...

Page 27: ...oll Server SET UP APP Enable App System ID Cloud Password Security Poll Server App Password SMS PHONEBOOK B Enable App Security No 0 AAAAAAAA Normal 0 _ Yes 1 0 No 1 Yes 1 Yes 0 No 1 High 0 Normal Enf...

Page 28: ...D ABCD ABCD Key Part 2 ABCD ABCD ABCD ABCD Key Part 2 ABCD ABCD ABCD ABCD View App Password Key SMS PHONEBOOK B Mobile Send Password key in a text Password sent successfully Key Part 1 ABCD ABCD ABCD...

Page 29: ...nternational dialling code e g 44 If you need to enter an international dialling code to send the key to a foreign SIM card use the a key to enter the symbol SMS Number SMS PHONEBOOK SMS Numbers User...

Page 30: ...ask Test Inputs Completed When using the Walk Test Input option to choose a specific Input to test the keypad will make an audible beep each time the Input is triggered WALK TEST Walk Test Areas Walk...

Page 31: ...u BLOCK REMOTE ARMING B Yes 1 0 No 1 Yes Block Remote Arming This function will block any attempt made to arm or disarm via the UDL software if enabled Block remote arm BLOCK REMOTE ARMING Block Remot...

Page 32: ...UDL BLOCK UDL Block UDL SYSTEM SOUNDS DEMO B 1 Yes 0 No No 0 System Sounds Demo Sound Demo Options SYSTEM SOUNDS DEMO Sounds Demo B PRESS A TO EXIT SAVE MAN MENU No Sound 00 00 No Sound 01 Chime Sing...

Page 33: ...ss the a key to exit Master Manager mode from any main menu item displayed in capital letters EXIT MANAGER MODE Enforcer BYPASS INPUTS Enforcer BYPASS INPUTS B A OR Time 10 09 c Time 10 09 c Enforcer...

Page 34: ...sed the panelwillsend an incorrectcommand message back to you Example SMS command send Description Example SMS command response Arming via SMS text command 1234 Arm A 1234 User Code Arm A Will arm in...

Page 35: ...utput Garage Door on Turns output named as Garage Door on OUTPUT Garage Door ON 1234 Output Garage Door Off 1234 User Code output Garage Door off Turns output named as Garage Door off OUTPUT Garage Do...

Page 36: ...nnected to the PC1 9999 UDL 9999 Engineer Code UDL The panel will make an outgoing data connection to the programmed PC1 number No response as the panel is already connected to the PC1 Inputs Inputs I...

Page 37: ...PGM1 KPD TRD Address 2 PGM1 KPD TRD Address 3 PGM1 ROX Address 0 PGM2 ROX Address 0 PGM3 ROX Address 0 PGM4 ROX Address 0 PGM5 ROX Address 0 PGM6 ROX Address 0 PGM7 ROX Address 0 PGM8 ROX Address 0 P...

Page 38: ...M3 RIX Address 2 PGM4 RIX Address 2 PGM1 RIX Address 3 PGM2 RIX Address 3 PGM3 RIX Address 3 PGM4 RIX Address 3 Users User Name Code Tag Keyfob User Name Code Tag Keyfob User Name Code Tag Keyfob 1 26...

Page 39: ...n a set state a access to the supervised premises or part thereof via an entry exit route shall be prevented or b opening the door to the entry exit route shall initiate an entry procedure App HomeCon...

Page 40: ...Notes 40 Enforcer User Guide 102017855 V01...

Page 41: ......