![HIKVISION iDS-9616NXI-I16/16S User Manual Download Page 41](http://html1.mh-extra.com/html/hikvision/ids-9616nxi-i16-16s/ids-9616nxi-i16-16s_user-manual_2132183041.webp)
Network Video Recorder User Manual
40
Figure 3-3
PoE Settings
The PoE ports are enabled with the short distance mode by default.
The bandwidth of IP camera connected to the PoE via long network cable (100 to 300
meters) cannot exceed 6 MP.
The allowed max. long network cable may be less than 300 meters depending on different
IP camera models and cable materials.
When the transmission distance reaches 100 to 250 meters, you must use the CAT5E or
CAT6 network cable to connect with the PoE interface.
When the transmission distance reaches 250 to 300 meters, you must use the CAT6
network cable to connect with the PoE interface.
Step 3
Click Apply.
3.3 Configure the Customized Protocols
Purpose:
To connect the network cameras which are not configured with the standard protocols, you can
configure the customized protocols for them. The system provides 16 customized protocols.
Step 1
Click Protocol at the top taskbar to enter the protocol management interface.