DS-TMG033 Barrier Gate Radar User Manual

 

 

Chapter 2 Barrier Gate Radar Installation 

2.1 Cautions 

 

The installation of anti-fall radar and capture-trigger radar must be perpendicular to driveway. 
The anti-fall radar is installed on the case beneath the arm of the barrier gate, while 
capture-trigger radar is installed on the card reader or individual upright tube. It is suggested 
to install the bottom edge of radar 0.6 meter (1.97 inch) above the ground, as shown in figure 
2-1. 

 

Figure 2-1

 

Figure 2-1 Barrier Gate Radar Installation Environment 

 

Barrier must be firmly installed with an inclination angle smaller than 5°. 

 

Do not block the front of the radar. 

 

Proper power supply. 

 

Do not hot plug in serial ports. 

 

If there is a guardrail outside driveway, fix the guardrail firmly. Do not use contraction band or 
traffic cone as guardrail, it is not stable and may cause waggling. 

 

Don’t place any objects in radar detection range, except arm of barrier gate. 

 

Recharge radar and update background clutter map timely if the environment changes. 

 

Extend the guardrail outside the barrier gate by a certain length L to guarantee barrier gate 
safety, as shown in figure 2-2. 

Summary of Contents for DS-TMG033

Page 1: ...DS TMG033 Barrier Gate Radar User Manual ...

Page 2: ...os mentioned below are the properties of their respective owners Legal Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THE PRODUCT DESCRIBED WITH ITS HARDWARE SOFTWARE AND FIRMWARE IS PROVIDED AS IS WITH ALL FAULTS AND ERRORS AND HIKVISION MAKES NO WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION MERCHANTABILITY SATISFACTORY QUALITY FITNESS FOR A PARTICULAR PURPOSE AND NON I...

Page 3: ...ference 2 This device must accept any interference received including interference that may cause undesired operation EU Conformity Statement This product and if applicable the supplied accessories too are marked with CE and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014 30 EU the LVD Directive 2014 35 EU the RoHS Directive 2011 65 EU 2012 19...

Page 4: ...nformation Input voltage should meet both the SELV Safety Extra Low Voltage and the Limited Power Source according to the IEC60950 1 standard Please refer to technical specifications for detailed information Do not connect several devices to one power adapter as adapter overload may cause over heating or a fire hazard Please make sure that the plug is firmly connected to the power socket If smoke ...

Page 5: ... peripherals A factory recommended HDD should be used for this device Improper use or replacement of the battery may result in hazard of explosion Replace with the same or equivalent type only Dispose of used batteries according to the instructions provided by the battery manufacturer Ensure to use the attached power adaptor only and not to change the adaptor randomly ...

Page 6: ...tallation 9 2 1 Cautions 9 2 2 Interface Explanation 10 2 3 Barrier Gate Radar Installation 11 2 3 1 Anti Fall Radar 11 2 3 2 Capture Trigger Radar 12 2 3 3 Cabling 13 2 3 4 Auto Calibration 14 Chapter 3 Configuration 15 3 1 Install Software 15 3 2 Configure Radar Parameters 16 3 3 Read and Clear Count 17 3 4 View Target Status 17 3 5 Other Operation 18 Chapter 4 FAQ 19 ...

Page 7: ...avoiding it falling down when there is vehicle or pedestrian passing The capture trigger radar is used to trigger the capture camera to capture the license plate picture Capture Trigger Radar Anti Fall Radar Figure 1 1 Barrier Gate Radar Components The barrier gate radar is applicable to parking lot entrance and exit of underground garage It can control the arm of the barrier gate to rise and fall...

Page 8: ...or the inductive loops the constructors have to damage the pavement in installation and maintenance After installation they have to repair the pavement again It requires high labor cost While for the radar the installation and maintenance do not need to damage the pavement and need little manual labor and short labor hour Vehicle and pedestrian can be distinguished The inductive loops can only rec...

Page 9: ... Figure 2 1 Figure 2 1 Barrier Gate Radar Installation Environment Barrier must be firmly installed with an inclination angle smaller than 5 Do not block the front of the radar Proper power supply Do not hot plug in serial ports If there is a guardrail outside driveway fix the guardrail firmly Do not use contraction band or traffic cone as guardrail it is not stable and may cause waggling Don t pl...

Page 10: ...ation between guardrail extending length and driveway width is shown in table 2 1 Table 2 1 Corresponding Relation between Guardrail Extending Length and Driveway Width Driveway Width W m Guardrail Extending Length L m 3 0 0 6 3 2 1 0 3 4 1 2 3 6 1 6 3 8 2 0 4 0 2 2 4 2 2 6 4 4 3 0 2 2 Interface Explanation Radar interfaces are shown as figure 2 3 ...

Page 11: ...White J2 2 Purple Calibration button input T R Green T R Blue 485 communication GND Black 12V Red 12 V power supply 2 3 Barrier Gate Radar Installation Barrier gate radar supports both external and internal installation Detailed installation is shown as below 2 3 1 Anti Fall Radar Anti fall radar must be longitudinally mounted Step 1 Install six welding studs on the rack as shown in figure 2 4 ...

Page 12: ...s Position Step 2 Embed sealing gasket into the edge of radar Step 3 Drive the welding studs into four fixing holes of radar and tighten the nuts Figure 2 5 Internal Installation of Anti Fall Radar 2 3 2 Capture Trigger Radar Step 1 Punch two mounting holes on the rack ...

Page 13: ...d hole into threaded hole Step 3 Fix capture trigger radar on rack and tighten screws Figure 2 7 Install Capture Trigger Radar 2 3 3 Cabling Connect radar plug to communication plug Connect 12 V to output positive terminal of 12 VDC power supply while connect GND to output negative terminal of power supply Connect capture trigger radar J1 1 and J1 2 to camera trigger terminal ...

Page 14: ...ate If delay fall is disabled you can choose not to connect But you have to ensure insulation Skip the below cabling if you do not use upper computer To view radar status in upper computer connect T R to the T R of 485 interface T R to the T R of 485 interface and 485 serial port cable to computer serial port 2 3 4 Auto Calibration Radar records background clutter automatically when charging Red i...

Page 15: ...erated on desktop as shown in figure 3 1 Figure 3 1 Software Installation Step 2 Run the ETGRadar icon to start the software and the interface is shown as figure 3 2 Configure Radar parameters 目标出入状态显示区 Connect or disconnect upper computer Target access displayed in animation Target access condition display area Figure 3 2 Software Interface Step 3 Connect devices 1 Click Device Connect a dialog b...

Page 16: ...re no pedestrians or cars pass in 5 seconds Green indicator stops flickering in 5 seconds when the calibration finished When Update timeout pops up or scene changes you have to conduct calibration again Step 5 Clear current count If you need to recount the traffic flow click Clear Current Count and click Yes in the pop up prompt to clear the traffic flow counting 3 2 Configure Radar Parameters Ste...

Page 17: ... Higher the sensitivity is stronger the radar identification ability is Radar of True sensitivity detects individual pedestrian while radar of False sensitivity detects multiple pedestrians and small electric car and small electric car underreporting can occur Step 2 Distribute Parameters Click Set to distribute parameters to radars Prompts of Set successfully indicates successful distribution Ste...

Page 18: ...DS TMG033 Barrier Gate Radar User Manual 18 3 5 Other Operation Click Device Disconnect to disconnect device and close software to stop viewing radar operating state ...

Page 19: ...eceived increases If not there are problems with serial port connection Please make sure serial port is connected properly and serial port parameters are configured correctly Step 2 If bytes received increases you have to charge and calibrate radar again Make sure there is no target in radar range when charging radar Relay won t jump when a target is detected Run upper computer to check whether by...

Page 20: ...DS TMG033 Barrier Gate Radar User Manual 20 ...

Reviews: