DS-PR1-60 User Manual
UM DS-PR1-60 090920NA
36
5.3.2
Multipoint Calibration
Before You Start
Arrange a staff person (Operation staff) to perform the calibration operation in the client software, and a
staff person (Calibration staff) to cooperate with the calibration.
1.
In the calibration page, select
Multipoint Calibration
as the calibration mode.
2.
Select calibration points (equally distributed) on the center line of the radar detection field, you can refer to
the following figure to select points.
Figure 5-9 Multipoint Distribution Instance
It is required to set three calibration points (equally distributed) when using multipoint
calibration.
3.
According to the calibration points, ask the calibration staff to move to a calibration point, and refer to step
2 to step 5 in
One Point Calibration
to calibrate the calibration point.
4.
When the first calibration point is calibrated completely, let the calibration staff move to the next
calibration point after the yellow track disappears. And then refer to step 2 to step 5 in
One Point
Calibration
to calibrate the calibration point. Follow this process to complete all calibration point
positioning in turn.