1. Download and install the iVMS-4200 client.

Note: Get the client software from the official website:www.hikvision.com.

2. Enter Device Management page, click “Device - Online Device”, select the device in the 

Online Device List, click Edit Network Settings,  change the port as 80, and click Add to Client.

Note: You should activate the device for the first usage. 

Set Up

1

2

3

Set up via Web Client

Input the device IP address in the address bar of the web browser.  Create a password to 

activate the device and log into the web client. 

Default IP Address when using mobile broswer in the AP mode:192.168.8.1. The device  must be in the AP mode. 

Default IP Address when connecting the network cable with computer directly :192.0.0.64

AC Power

Power On
System Fault

No Fault

Panel is added to Hik-connect account

Panel is not added to Hik-connect account

Armed

Disarmed

Alarm Occurred

Indicators

Components

Device Tampered

No Alarm

Power Off

Status

Link

Arm/Disarm

Alarm

Note: Remove the rear cover, and some of the components and interfaces are on the rear panel. 

Reset: Power on the device, the yellow status indicator will flash 3 times. Hold the reset button for 5 s to reset 

the device.

1

2

2

2

3

5

4

1. Loosen the screw on the top, press the lock nut, and open the case of the control panel.

2. Route the cables, and secure the rear cover in the installation position with the supplied 

screws. 

3. Fix the SIM card module (should be purchased separately)  with four plastic bolts.

4. Fix the telephone module (should be purchased separately) with two plastic bolts.  

5. Wire the cables.

1. Log into the App Store or Google Play and input Hik-Connect to search and install the 

mobile client. 

2. Log into the APP with Hik-Connect account.

3. Tap Add Device. Scan the device QR code on the rear panel(on the lable).

4. Tap Connect to a Network.  Select Wireless Connection (AP) as the connection mode.

5. Push the AP/STA mode switch to the AP position, tab Confirm.

6. Tap Connect to Wi-Fi on the promt-up window. Select and connect to a stable Wi-Fi ,  and 

click Next.

7. Create a password to activate the device.

8. Push the AP/STA mode switch to the STA position.

Note: You need to enter the Verification Code (on the device lable which is pasted on the rear panel) before 

activation if you add the device by entering the device serial No.(SN).

Battery 

Connector

Network 

Interface

Power 

Interface

Lock Nut

AP&STA 

Switch

TAMPER 

Switch

Wiring 

Terminal

2

12

2

13

2

11

Reset 

Button

2

10

2

9

2

8

2

7

2

6

You can view the alarm video via APP and email. 

For detailed settings, refer to Security 

Control Panel User Manual.

Reboot the device

. Boot the device, and hold the reset button for 5s after the Fault indictaor 

flashes 3 times. The device will prompt a message to indicates the operation status. 

TAMPER Screw

It is compulsory to secure the TAMPER screw.

Specification

3

2

1

2

21

22

2

5

2

6

2

8

27

23

24

2

12

2

13

2

11

2

10

2

8

2

7

2

6

2

1

2

2

2

3

2

4

2

5

2

9

2

5

2

8

CAUTION

RISK OF EXPLOSION IF 

BATTERY IS REPLACED BY AN 

INCORRECT TYPE

DISPOSE OF USED BATTERIES 

ACCORDING TO THE 

INSTRUCTIONS

CAUTION

SUITABLE FOR MOUNTING ON 

CONCRETE OR OTHER 

NON-COMBUSTIBLE SURFACE ONLY

AP

STA

AP

STA

1

2

3

4

2

3

......

1

2

3

Power Supply

Network

4

Telephone Module Wiring

AP

STA

AP

STA

Product Information

6. Connect the battery to the control panel.

 

Note: The condition of no SIM card, no battery, AC power off, or network disconnected, will cause Control Panel Fault.

7. Fix the power cables with the cable clip.

8. Close the control panel, and tighten the top screws to complete the installation.

Alarm Input/Alarm Output/RS-485 Wiring

2

1

Alarm Input Wiring 

2

2

a.

Alarm Output Wiring 

2

3

RS-485 Wiring: Wireless Receiver, keypad, etc.

NC 

D

etect

o

r

b.

c.

N

O

 

D

etect

o

r

Unoccupied Zone 

The AP mode is only Supported by device with Wi-Fi function.

Hybrid Security Control Panel

1. Click System-Network Camera, and you can add cameras for the control panel.

2. Enter the “Device Management” page, select a zone, and select a camera to link with the zone.

You can also link a camera with the zone via APP, refer to the Security Control Panel User Manual 

for details.

The function varies depends on the model of device.

Alarm

Lamp

Alarm

Lamp

Alarm

Lamp

Alarm

Lamp

Siren

Keypad

12VDC

Power Adapter

N.C

N.O

2K2

EOL

N.C

N.O

2K2

EOL

N.C

N.O

2K2

EOL

N.C

N.O

2K2

EOL

N.C

N.O

2K2

EOL

N.C

N.O

2K2

EOL

N.C

N.O

2K2

EOL

N.C

N.O

2K2

EOL

Z1

G

Z2

Z3

G

Z4

Z5

G

Z6

Z7

G

Z8

NO/NC1 COM1

12V_AUX

12V_BELL

485+

12V

G

G

485

G

NO/NC2 COM2 NO/NC3 COM3 NO/NC4 COM4

CON101 L

N

220V~

2

1

Dry Contact

AUX+

AUX-

D- D+

AUX+

AUX-

OR

D- D+

C1

PGM1

……

2

2

2

3

1

Telephone Module

Telephone Line Cut Off Indicator

Power Indicator

Telephone

Line

Telephone

Line

Telephone

Telephone

Set up via APP

DS-PHA20-P
DS-PHA64-P

DS-PHA20-W2P
DS-PHA64-W4P

Wireless Detector
Wireless Output expander

Siren

Keyfob

Partition

Zone

Alarm output

Alarm output

Scheduled arming/disarming
SMS notification
(with 3G/4G/GPRS module)

Network camera accessing

N/A

2 (DS-PHA20)
4 (DS-PHA64)

Application

Protocol

Wired network
Cellular Network
(with 3G/4G/GPRS module)
Standard

N/A

802.11b/g/n

Encryption

N/A

64/128-bit WEP,WPA/

WPA2,WPA-PSK/WPA2-

PSK,WPS

Configuration

N/A

AP Mode

Distance

N/A

Indoor: 

 50 m

Outdoor: 

 100 m

TAMPER Switch
Network Interface
Telephone Interface

RS-485 Terminal

Siren Power Interface

Battery Interface

User

Tag
Operation Temperature
Operation Humidity

Dimension (W × H × D)

User

12

Model

Device
connection

Up to 16/56
Up to 8
1 wired siren (on-board connection)
2 wireless sirens
8, valid operation interval: 3 s

Hybrid Security Control Panel with Plastic Case

Alarm input

4 (DS-PHA20)
8 (DS-PHA64)
4 on-board zones , and 16 wired/wireless zones expadable(DS-PHA20),
or
8 on-board zones, and 56 wired/wireless zones expadable(DS-PHA64)
2 on-board outputs, and 18 wired/wireless outputs expadable (DS-PHA20),
or
4 on-board outputs, and 60 wired/wireless outputs expadable (DS-PHA64)

Function

Supported

Supports up to 8 mobile phone numbers

1, PSTN expander interface
1, extended up to 20 inputs/outputs (with RS-485 module),
and 9 wired keypads extendable (DS-PHA20),
or
1, extended up to 64 inputs/outputs (with RS-485 module),
and 9 wired keypads extendable (DS-PHA64)

1, 12V

Lithium battery (-P model)

Application &
Protocol

iVMS-4200 (client software)
Hik-Connect (mobile client)
ISAPI: Supports client software and web client
Cloud P2P: Supports cloud P2P privacy protocol
DC09: ARC accessible (CID/SIA)

Network

10M/100M Ethernet

Supports report push- notification to ARC & Cloud

Installer: 1
Administrator: 1
Manufactuer:1
Operator: 13 (DS-PHA20), 45 (DS-PHA64)

Others

–10 °C to 55 °C (-4 °F to +122 °F)
10% to 90% (No condensing)
Plastic Case: 220 mm (8.6") × 152 mm (6.0") × 31.5 mm(1.2")

Wi-Fi

Interface &
Component

1, front cover tamper-proof
1, RJ45 10M/100M Ethernet Interface

2

a

2

b

2

c

2

2.2K

NC

C

Z

C

Perip

h

eral Securit

y

 

D

etect

o

r

2.2K

N

O

C

Z

C

Security Control Panel

Security Control Panel

Security Control Panel

Perip

h

eral Securit

y

 

D

etect

o

r

Z

C

d.

Tamper-proof

Note: The 868 Mhz wireless siren can be enrolled to the hybrid control panel via the wireless receiver that is at the address of 9.  

CAUTION

COPER OR COPER WIRE CANNOT BE 

EXPOSED AT THE ELECTRICAL TERMINAL 

CAUTION

A TWO-POLE DISCONNECTED 

DEVICE (BREAKER) SHALL BE 

PROVIDED WHEN INSTALLED

CAUTION

CABLES CAN ONLY BE ROUTED 

THROUGH THE REAR PANEL. DO NOT 

ROUTE THE ANTENNA WIRE THROUGH 

THE ELECTRICAL BOARD

CON101

L

N

220V~

NULL

Line

Caustic

Line

GND

4

AP

STA

AP

STA

UD15863B-B

©2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.

About this Manual

The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information 

hereinafter are for description and explanation only. The information contained in the Manual is subject to change, 

without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision 

website (https://www.hikvision.com/). 

Please use this Manual with the guidance and assistance of professionals trained in supporting the Product.

Trademarks

                         and other Hikvision's trademarks and logos are the properties of Hikvision in various jurisdictions. Other 

trademarks and logos mentioned are the properties of their respective owners.

Disclaimer

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS 

HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES 

NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR 

FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL 

HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, 

AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION 

OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING 

NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION 

HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.

YOU ACKNOWLEDGE THAT THE NATURE OF INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL 

NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM 

CYBER-ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL 

PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.

YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR 

ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS 

PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, 

RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL 

NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS 

OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES 

IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN 

RIGHTS ABUSES.

IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.

This product and - if applicable - the supplied accessories too are marked with "CE" and 

comply therefore with the applicable harmonized European standards listed under the RE 

Directive 2014/53/EU, the EMC Directive 2014/30/EU, the LVD Directive 2014/35/EU,  the 

RoHS Directive 2011/65/EU

2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as 

unsorted municipal waste in the European Union. For proper recycling, return this product to 

your local supplier upon the purchase of equivalent new equipment, or dispose of it at 

designated collection points. For more information see: www.recyclethis.info
2006/66/EC (battery directive): This product contains a battery that cannot be disposed of 

as unsorted municipal waste in the European Union. See the product documentation for 

specific battery information. The battery is marked with this symbol, which may include 

lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return 

the battery to your supplier or to a designated collection point. For more information 

see:www.recyclethis.info

FCC Information

Please take attention that changes or modification not expressly approved by the party responsible for 

compliance could void the user’s authority to operate the equipment.

FCC compliance: This equipment has been tested and found to comply with the limits for a Class B 

digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable 

protection against harmful interference in a residential installation. This equipment generates, uses 

and can radiate radio frequency energy and, if not installed and used in accordance with the 

instructions, may cause harmful interference to radio communications. However, there is no 

guarantee that interference will not occur in a particular installation. If this equipment does cause 

harmful interference to radio or television reception, which can be determined by turning the 

equipment off and on, the user is encouraged to try to correct the interference by one or more of the 

following measures:

—Reorient or relocate the receiving antenna.

—Increase the separation between the equipment and receiver.

—Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected.

—Consult the dealer or an experienced radio/TV technician for help.

This equipment should be installed and operated with a minimum distance 20cm between the 

radiator and your body.

FCC Conditions

This device complies with part 15 of the FCC Rules. Operation is subject to the following two 

conditions:

1. This device may not cause harmful interference.

2. This device must accept any interference received, including interference that may cause undesired 

operation

2.2K

Ω

2.

2K

Ω

Z

C

N

C

N

O

T

A

M

PER

Detector

d

2

e

e.

Dual-Zone Series Connection

f.

Dual-Zone Parallel Connection

2.2kΩ

Z

C

NC

C

8.2kΩ

NC

C

Security 

Control Panel

Local Zone

Local Expanding Zone

2

f

2.2kΩ

Z

C

Local Zone

Security 

Control Panel

8.2kΩ

Local Expanding

 Zone

NO           C

NO           C