3.4.4
Main Control Board Serial Port ID Description
Purpose:
You can use the jumper cap on the main control board to switch the interface communication
mode. For details about switching between RS-232 and RS-485 communication type, see 4.4
Switching RS-485/RS-232 Mode.
According to the picture above, the RS-485 serial port corresponds to UART2 and UART3. RS-232
serial port is corresponded to UART7 and UART8. Wiring Interface is corresponded to UART1,
UART4, UART6, UART6, and Lane.
The main control board descriptions are as follows:
UART2/UART3 Jumper Cap:
Reserved serial port. Use the jumper cap to switch the serial
port communication mode. You can switch between the
RS-485 communication mode and the RS-232
communication mode. By default, it is in RS-485
communication mode.
UART6 Jumper Cap:
Use the jumper cap to switch the serial port communication
mode with the slave lane controller. You can switch between
the RS-232 communication mode and the RS-485
communication mode. By default, it is in RS-232
communication mode.
UART5 Jumper Cap:
Use the jumper cap to switch the serial port communication
mode with the slave lane controller. You can switch between
the RS-484 communication mode and the RS-232
communication mode. By default, it is in RS-485
communication mode.
Summary of Contents for DS-K3B601-L Series
Page 1: ...Swing Barrier Quick Start Guide...
Page 16: ...Swing Barrier Quick Start Guide 8 3 4 3 Main Control Board Terminal Description...
Page 23: ...Swing Barrier Quick Start Guide 15 Entering Wiring Exiting Wiring...
Page 25: ...Swing Barrier Quick Start Guide 17...
Page 38: ...Swing Barrier Quick Start Guide 30 UD08976B B...