Swing Barrier
·
Quick Start Guide
6
The picture displayed below describes the interconnecting cable’s wiring diagram.
Notes:
The supplied interconnecting cable length is 3.75 m. If you need a longer one, ask our
technique supports or sales and purchase 5.5 m interconnecting cables.
The inner diameters of the low voltage conduit and the high voltage conduit should be larger
than 30 mm. If there is a high-power peripheral (for authentication) installed on the left
pedestal (according to the picture displayed above), you should increase the inner diameter of
the high voltage conduit.
General burying method: Bury one network cable and one AC power cord for the right pedestal
and bury one network cable and one AC power cord for the central pedestal before installation.
If no AC power cord buried independently, you should bury an AC power cord between the
right pedestal and the central pedestal.
If you want to bury both of the AC power cord and the low voltage cable at the entrance side,
the two cables should be in separated conduits to avoid interference.
If all wires of the interconnecting cable have connected with peripherals and more peripherals
are required to connect, you should increase the conduit diameter or bury another conduit for
the external cable.
The external AC power cord should be double-insulated.
Summary of Contents for DS-K3B601-L Series
Page 1: ...Swing Barrier Quick Start Guide...
Page 16: ...Swing Barrier Quick Start Guide 8 3 4 3 Main Control Board Terminal Description...
Page 23: ...Swing Barrier Quick Start Guide 15 Entering Wiring Exiting Wiring...
Page 25: ...Swing Barrier Quick Start Guide 17...
Page 38: ...Swing Barrier Quick Start Guide 30 UD08976B B...