User Manual of DS-9500 Series NVR
61
Rebuilding Array Manually
When the system has detected HDD exception or the array is in
Degraded
status, you can select the idle physical
HDD for manual rebuilding of array.
Step3:
Click the
Virtual Disk
tab to
return to the Virtual Disk interface to
check the rebuilding status under Task
bar.
Step1:
Select array for rebuilding.
1)
Enter the RAID Settings menu by clicking
Config > Remote Config >RAID Configuration.
2)
Select the
Array
tab to enter the Array interface.
3)
Select the array for rebuilding.
4)
Click the
Rebuild
button to enter Rebuild Array
interface.
Step2:
Select physical HDD for array rebuilding.
1)
Select the physical HDD for array rebuilding.
2)
Click the
OK
button to confirm the array
rebuilding
Note:
Make sure virtual disks have been created
before operating array rebuilding; otherwise,
corresponding message box will pop up.
Summary of Contents for DS-9500 Series NVR
Page 1: ...DS 9500 Series NVR USER MANUAL Version 1 3 1 ...
Page 9: ...User Manual of DS 9500 Series NVR 6 C H A P T E R 1 Introduction ...
Page 15: ...User Manual of DS 9500 Series NVR 12 C H A P T E R 2 Network Parameters Configuration ...
Page 19: ...User Manual of DS 9500 Series NVR 16 C H A P T E R 3 ActiveX Control Installation ...
Page 21: ...User Manual of DS 9500 Series NVR 18 C H A P T E R 4 User Login and Exit ...
Page 23: ...User Manual of DS 9500 Series NVR 20 C H A P T E R 5 Preview ...
Page 28: ...User Manual of DS 9500 Series NVR 25 C H A P T E R 6 PTZ Control ...
Page 30: ...User Manual of DS 9500 Series NVR 27 C H A P T E R 7 Playback ...
Page 35: ...User Manual of DS 9500 Series NVR 32 C H A P T E R 8 Log Search ...
Page 37: ...User Manual of DS 9500 Series NVR 34 C H A P T E R 9 Configuration ...
Page 71: ...User Manual of DS 9500 Series NVR 68 C H A P T E R 10 Appendix ...