Digital Video Recorder User Manual
72
Table 3-3
Priorities of Interfaces for Other Series
S.N
VGA/HDMI CVBS
Main
output
Auxiliary
output
1
√
√
VGA/HDMI
CVBS
2
√
×
VGA/HDMI
3
×
√
CVBS
√
means the interface is in use,
×
means the interface is out of use or the connection is
invalid. And the HDMI, VGA and CVBS can be used at the same time.
For DS-7300/8100/9000HUHI-F/N series, when CVBS is used as the main output, the
VGA/HDMI1 and HDMI2 interfaces can only output the live view.
3.2.1
Using the Mouse in Live View
You can refer to Table 3-4 for the description of mouse operation in live view mode.
Table 3-4
Mouse Operation in Live View
Name
Description
Menu
Enter the main menu of the system by right clicking the
mouse.
Single Screen
Switch to the single full screen by choosing channel number
from the dropdown list.
Multi-Screen
Adjust the screen layout by selecting from the dropdown list.
For DS-7300/8100/9000HUHI-F/N series DVR, if the sum of the
analog and IP channels exceeds 25, up to 32-window division
mode is supported for the VGA/HDMI1 output.
Previous
Screen
Switch to the previous screen.
Next Screen
Switch to the next screen.
Start/Stop
Auto-Switch
Enable/disable the auto-switch of the screens.
The
dwell time
of the live view configuration must be set
before using Start Auto-Switch.
Start
Recording
Start recording of all channels, Continuous Record and
Motion Detection Record are selectable from the dropdown