Digital Video Recorder User Manual
208
If the hot spare disk has not been configured, you can rebuild the array manually to
restore the array when the virtual disk is in Degraded status.
Step 1
Enter the Array Settings interface. The disk 3 is lost.
Menu > HDD > RAID > Array
Figure 13-13
Array Settings Interface
Step 2
Click Array tab to return to the Array Settings interface and click
to
configure the array rebuild.
At least one available physical disk should exist for rebuilding the array.
Figure 13-14
Rebuild Array Interface
Step 3
Select the available physical disk and click OK button to confirm to rebuild the
array.
Step 4
The “Do not unplug the physical disk when it is under rebuilding” message box
pops up. Click OK button to start rebuilding.
Step 5
You can enter the Array Settings interface to view the rebuilding status.
Step 6
After rebuilding successfully, the array and virtual disk will restore to
Functional.
13.3 Deleting Array
Deleting array will cause to delete all the data saved in the disk.