User Manual of DS-6600 Audio/Video Encoder
16
DS-6600 HFI-JX:
Figure 2.6 Rear Panel of DS-6600HFI-JX
Table 2.6 Rear Panel of DS-6600HFI-JX
Interface
Connections
1
VIDEO IN
BNC connectors for video input.
2
LAN
10M/100Mbps self-adaptive UTP Ethernet interface.
3
ALARM IN
Relay alarm input.
ALARM OUT
Relay alarm output.
RS-485
RS-485 half-duplex interface
4
LINE IN
3.5mm voice talk input interface for connection to active pick-up,
microphone, etc.
5
AUDIO OUT
3.5mm audio output interface for connection to audio output device,
e.g., loudspeaker, etc.
6
POWER
220VAC power supply
7
GND
Grounding
2.3 Alarm Connections
2.3.1 Alarm Input Connections
DS-6600 supports the
open/close
relay input as the alarm input mode. For the alarm input signal not in open/close
relay signal mode, please follow the connections shown as below:
Alarm input connections for Emerson Alarm: