2.3.2 Alarm Output Connections
DS-6300DI-B supports the
open/close
relay input as the alarm output mode. The alarm input can be selected to
NO
or
NC
. Different alarm output connection methods are applied to the AC or DC load,
please refer to the following
diagram:
Alarm output connections diagram:
Please note the different connections of JJ1 shown above.
For DC load, JJ1ca be safely used both in
NC
and
NO
methods, and it is recommended to use within the limit of
12V/1A. For external AC input, JJ1 must be open. The motherboard provides two jumpers, each corresponding to
one alarm output. And both of two jumpers are factory set to be connected.
2.3.3 Signal Line Connections
DS-6300DI-B provides the green terminal plug for connecting signal lines. Follow the instructions shown below:
1.
Disconnect the green terminal plug from the terminal socket on the device;
2.
Use the standard screwdriver to loosen the screws on the plug, and then insert signal lines to the plug and under
the spring washers, and finally tighten the screws.