16/24-Port 100M Long-Range PoE Switch Quick Start Guide
3
indicator
Flashing
The 1000M RJ45 port is transmitting data.
Unlit
No 1000M RJ45 port connected or connection is abnormal.
G2 port
indicator
Solid on
The SFP fiber optical port is connected.
Flashing
The SFP fiber optical port is transmitting data.
Unlit
No SFP fiber optical port connected or connection is abnormal.
LINK/ACT
indicator
Solid on
RJ45 port is connected.
Flashing
RJ45 port is transmitting data.
Unlit
RJ45 port is disconnected or connection is abnormal.
PoE indicator
Solid on
The switch provides power supply to PD normally.
Unlit
The switch is disconnected to PD, or provides power supply to PD
abnormally.
PoE-MAX
indicator
Solid on
/Flashing
The output power of the switch is about to reach the upper limit.
The power supply may be abnormal if more devices are connected.
Unlit
The switch provides power supply to PD normally.
DIP Switch
DIP switch can be switched to two statuses: standard model, and extend model.
Table 1-3
DIP Switch Model
Model
Function
Standard
The corresponding port supports network transmission of
up to 100 m, and the speed rate of the port is 100 Mbps.
Extend
DS-3E0318P-E/M(B): Extend (9-16)
DS-3E0326P-E/M(B): Extend (17-24)
The 9 to 16 ports of DS-3E0318P-E/M(B) and the 17 to 24
ports of DS-3E0326P-E/M(B) support network transmission
of up to 250 m, and the speed rate of the port is 10 Mbps.
PoE Ports
100M PoE ports are used for other PoE devices connection via network cables.
Ensure that your devices powered via the PoE port have their shells protected and fire-proofed,
because the switches are not compliant with the Limited Power Source (LPS) standard.
G1 Port/G2 Port
G1 port is a 1000M RJ45 port used for other devices connection via network cables.
G2 port is a 1000M SFP fiber optical port used for other devices connection via optical fiber
when plugged into with an optical module.