Video Security Control Panel User Manual
--40--
Control Panel Time Settings
3.1.8
For control panel time settings, please refer to the command below.
472 2013 01 01 08 00 00 #
1
2
4
6
3
5
7
8
{1}
Control Panel Time Settings Programming Address: 472
{2}
Year
{3}
Month
{4}
Day
{5}
Hour
{6}
Minute
{7}
Second
{8}
End the command.
Control Panel IP Settings
3.1.9
For control panel IP configuration, please refer to the command below.
473 192 000 000 064 #
1
2
3
5
4
6
{1}
Control Panel IP Settings Programming Address: 473.
{2}
Unit 1
{3}
Unit 2
{4}
Unit 3
{5}
Unit 4.
{6}
End the command.
The IP address programming includes 12 bytes. The 1 to 12 place represents the IP address of the control panel.
Each unit of the IP address includes 3 bytes. You should enter 0 if the entered address is less than 3 bytes for each
unit for complement. For example, you should enter 192 002 028 066 for validating the IP address of 192.2.28.66.