Control Panel User Manual
35
3.1.6
Alarm Receiver Phone Number Settings
The control panel supports two dialing accounts. The maximum length of
dialing number of each account is 31 digits. The command is shown as follows.
460 E0
∙∙∙∙∙∙
0 #
1
2
3
{1}
Programming Address of Phone Number of Alarm Connecter:
460~463
Address
Command
Description
Address
Command
Description
460
Alarm Center1
Phone Number
Programming
Address
462
Alarm Center2
Phone Number
Programming
Address
461
463
A telephone number is separated into two segments. The 460 and 461 group
represents the dialing number which is connected with alarm center1. The
462 and 463 group represents the dialing number which is connected with
alarm center2.
{2}
The dialing number is 16 digits.
All the telephone number should be end with *4.
The length of the each center number is 31 digits, and the
entering format should be {No.} + {Dwell Time} + {ext.No.}
The
default
center
number
is
E0000000000000000000000000000000.
{3}
End the command.
Example 1
:
If
the
tele-phone
number
is
0571-88075998,
you
can
enter
460057188075998*4# with the keypad for completing the configuration.
Example 2
:
If the telephone number is 17951-88075998, there are two steps to set the
Summary of Contents for DS-19A08-F/Kx
Page 1: ...Control Panel User Manual 1 UD 6L0206D1044A02 Network Security Control Panel User Manual...
Page 13: ...Control Panel User Manual 13 Chapter 2 Installation and Wiring 2 1 Main Board Overview...
Page 100: ...Control Panel User Manual 100 2 Click to enter the interface of adding a network user...
Page 130: ...Control Panel User Manual 130...
Page 156: ...Control Panel User Manual 156...