background image

 

Title: 

How to Confirm Fault Type When 
Control Panel in Zone Fault Status 

Version: 

v1.0 

Date: 

7/11/2017 

Product: 

Alarm Device 

Page: 

1 of  3 

 

 
Description 

 

 

When control panel is  in disarm status, it shows “Zone Fault” for some zones. In 

this case, control panel can not arm system successfully.

 

 

Problem Checking Flow  

 

Zone Fault

Detector is in 

alarm

Remove Detector, 

Replaced with an 

EOL directly 

Connect to zone 

terminal

Fault 

Disappears?

Measure Voltage 

between zone

 s 

terminal Z and G

故障是否消失

Keep Detector in 

Normal Statues, 

Fault 

Disappears?

NO Problem in 

Detector and 

Control Panel

探测器故障

Detector Fault or 

Wiring Fault

总线接线问题

Voltage in 

Normal Range

Detector Fault or 

Wiring Fault

Control Panel Fault

Yes

NO

No

NO

NO

NO

Yes

Yes

Yes

 

Reviews: