Entry Delay 2
Set a value for Entry Delay 1 and Entry Delay2. Entry delay is a
time concept. If entry delay is configured for the delayed zone,
when you enter an armed delayed zone, the zone alarm will
not be triggered until the end of entry delay.
Note
After set value for Entry Delay 1 and Entry Delay 2, you should
set the entry delay of a specific zone to the value of Entry
Delay 1 or Entry Delay 2.
Exit Delay
Set exit delay for the delayed zone. If exit delay is configured
for the delayed zone, after you arm the zone on the indoor
unit, you can exit the zone without triggering alarm until the
end of exit delay.
Siren Delay Time (Perimeter Alarm)
The duration that the siren lasts when perimeter alarm is
triggered.
Note
For details about perimeter alarm, see the user manual of the
security control panel.
4.4.11 Check System Status (Zone Status/
Communication Status)
You can view the zone status and the communication status via
the mobile client.
View Zone Status
In the Partition page, tap Zone to enter the Zone tab. You can
view the each zone's status in the list.
Communication Mode
In the Partition page, tap → Device Information to enter the
page. You can view the device communication status, including
the battery, Ethernet network, Wi-Fi, mobile network, data usage
and so on.
4.4.12 Check Alarm Notification
When an alarm is triggered, and you will receive an alarm
notification. You can check the alarm information from the
mobile client.
Before You Start
• Make sure you have linked a zone with a detector.
• Make sure the zone is not bypassed.
• Make sure you have not enabled the silent zone function.
Steps
1. Tap Notification in the mobile client to enter the page.
51