ID7000 Series Smart Code Reader User Manual
39
Note
For specific trigger sources, refer to the actual device you got.
9.3.2 Enable Internal Trigger Mode
In the internal trigger mode, the device acquires images via its internal signals. You have 2 methods
to enable the internal trigger mode:
●
Click
I/O Control Settings
→
Input
→
Trigger Mode
, and select
Off
as
Trigger Mode
.
●
In the live view page, click
to enable the internal trigger mode.
9.3.3 Enable External Trigger Mode
In the external trigger mode, the device acquires images via external signals like software signal and
hardware signal. You have 2 methods to enable the external trigger mode:
●
Click
I/O Control Settings
→
Input
→
Trigger Mode
, and select
On
as
Trigger Mode
.
●
In the live view page, click
to enable the external trigger mode.
9.3.4 Set Trigger Mode
The device supports free trigger mode, line trigger, frame trigger, and line plus frame trigger.
Free Trigger Mode
In the free trigger mode, the device generates trigger signals by itself, and outputs images
continuously in accordance with the configured frame rate.
Steps
1. Right click the device in the
Device Connection
, and click
Feature Tree
.
2. Go to
Trigger and IO Control
→
Trigger Selector
.
3. Set
Trigger Mode
as
Off
after selecting
Line Start
and
Frame Burst Start
as
Trigger Selector
.
Figure 9-8 Free Trigger Mode
Frame Trigger Mode
Steps
1. Right click the device in the
Device Connection
, and click
Feature Tree
.