ID6000 Series Smart Code Reader User Manual
39
Figure 7-25 Enable Line Out Inverter
7.6.3 Set Event Source
Note
For different models of camera, the event source parameters may be different, and the actual
product you purchased shall prevail.
The device supports outputting different trigger signals according to the event source you select.
Click I/O Control Settings → Output → Line Out Activation Event to select event source.
The device supports following event sources, including Off, AcquisitionStartActive,
AcquisitionStopActive, Frame BurstStartActive, FrameBurstStopActive, ExposureStartActive,
SoftTriggerActive, HardTriggerActive, CounterActive, TimerActive, NoCodeRead, ReadSuccess,
LightStrobeLong, and LightContinued.
Note
●
Off refers to no event source.
●
You need to set different parameters when selecting these event sources.