CoaXPress Area Scan Camera
·
User Manual
63
Steps:
1.
Click Analog Control > Gamma Selector.
2.
Select User as Gamma Selector.
3.
Enable Gamma Enable to enable it.
4.
Enter Gamma according to actual demands, and its range is from 0 to 4.
Figure 11-26
Set User Mode
You can set sRGB mode as shown below.
Steps:
1.
Click Analog Control > Gamma Selector.
2.
Select sRGB as Gamma Selector.
3.
Enable Gamma Enable to enable it.
Figure 11-27
Set sRGB Mode
11.17 Set Sharpness
The sharpness function may differ by camera models.
The camera supports sharpness function that can adjust the sharpness level of the image edge, You
can set sharpness as shown below.
Click Analog Control > Sharpness Enable, enable Sharpness Enable, and enter Sharpness
according to actual demands.
Summary of Contents for CoaXPress
Page 1: ...CoaXPress Area Scan Camera User Manual ...
Page 10: ...CoaXPress Area Scan Camera User Manual x Appendix A Camera Parameter Index 85 ...
Page 41: ...CoaXPress Area Scan Camera User Manual 31 Figure 8 18 Set Trigger Debouncer ...
Page 82: ...CoaXPress Area Scan Camera User Manual 72 Figure 11 39 Other Corrections ...
Page 102: ...UD26060B ...