CoaXPress Area Scan Camera
·
User Manual
23
Steps:
1.
Click Digital IO Control.
2.
Select Line 2 as Line Selector, and Input as Line Mode to set line 2 as input signal.
Figure 8-6
Set Line 2 as Input Signal
3.
Select Line 2 as Trigger Source.
Figure 8-7
Set Hardware Trigger
8.4.4 Set Counter Trigger
The counter trigger provides frequency division to the external trigger signal. You can set counter
trigger as shown below.
1.
Click Acquisition Control > Trigger Selector.
2.
Select On as Trigger Mode.
3.
Select Counter 0 as Trigger Source.