CameraLink Area Scan Camera
·
User Manual
43
If the VCC of NPN device is 24 VDC, and it is recommended to use 1 KΩ to 4.7 KΩ pull-up resistor.
If the VCC of NPN device is 12 VDC, and it is recommended to use 1 KΩ pull-up resistor.
Camera Power
Supply
Opt-Iso out
Camera Power
Ground
PWR
VCC
Device Power
Supply
Signal Line
Device Power
Ground
NPN Device
I/O Ground
GND of PWR
GND of VCC
Figure 7-12
Line 1 Connecting to NPN Device
7.2.3 Line 2 Wiring
As bi-direction I/O Circuit, Line 2 can be used as both input signal and output signal.
Type IV camera and type V camera do not have bi-direction I/O function.
Line 2 Configured as Input
When the camera uses Line 2 as hardware trigger source, wirings are different with different
external devices of input signal.
PNP Device
It is recommended to use 330 Ω pull-down resistor.
Camera Power
Supply
Bi-direction
I/O
Camera Power
Ground
PWR
VCC
Device Power
Supply
Signal Line
PNP Device
GND of PWR and
VCC
Device Power
Ground
Figure 7-13
Line 2 Connecting to PNP Device as Input
NPN Device
If the VCC of NPN device is 24 VDC, and it is recommended to use 1 KΩ to 4.7 KΩ pull-up resistor.
If the VCC of NPN device is 12 VDC, and it is recommended to use 1 KΩ pull-up resistor.