48
Enforcer V10 Programming Guide
NUMBER & TYPE
OPERATION
20
Keyswitch Latched*
Accepts input from keyswitch (or equivalent) to Set/Unset the
Set modes assigned to it. Setting includes normal exit time, etc.
Requires latching action switch.
21
Entry Shock Input
Active when system set. Works in conjunction with EE input type for
detection of forced entry. See page 35 for details.
23
Keyswitch Pulsed*
Accepts input from keyswitch (or equivalent) to Set/Unset the Set
modes assigned to it. Requires momentary action switch to toggle
set/unset state.
32
Flood
This input type will work as a 24hr input, any inputs that are
programmed for Flood will activate the external siren.
42
Medical
This input type will work as a 24hr input, any inputs that are
programmed for Medical will activate the external siren.
44
ATE Line Fail
Once a ATE line fail has been recognised the input will open.
*The use of these inputs will make the system unable to comply with EN50131-1 Grade 2
#These input types cannot be bypassed.
Entry Shock Input Type (21)
This input type is designed specifically for use with systems installed using BS8243 option 6.4.5.
This input type is always used in conjunction with an Entry/Exit input. The Entry/Exit input is a door contact on the
initial entry door, and the Entry Shock input is a non-latching shock sensor fitted to the door frame in the vicinity of
the lock. If the initial entry door is subjected to gross attack and forced open, then at the expiry of entry time only
one further intruder input need to be activated to signal a sequentially confirmed alarm – the Entry Shock input
counts as the first to alarm. The Entry/Exit door contact must be opened with 10 seconds of the shock detector
triggering for the Entry Shock response to apply. Triggering the Entry Shock input in isolation will NOT generate an
alarm of any kind.
APPENDIX C. TIMERS
TIMER
FUNCTION
RANGE
Entry Time
Entry time for each area. (if programmed as the input type ‘Final
Exit’)
0 – 255 seconds
Exit Time
Exit time for each area.
0 – 255 seconds
APP Exit Time
Exit time when set via the Home app
0 – 199 seconds
Siren Time
Cut off time for external sounder. Separate for each area.
2 – 15 minutes
Siren Delay
Delay after intruder alarm before siren live. Not valid within 3
minutes of final arm or after entry time started.
0 – 20 minutes
Confirm Time
Time period during which a second activation must occur to
qualify as ‘sequentially confirmed’ alarm. NOTE: BS8243 specifies
a confirm time between 30 and 60 minutes. This also can be
used in conjunction with testing an omit signal.
1 – 99 minutes
HU Confirm Time
Time period during which a second activation on a hold alarm
must occur to qualify as ‘sequentially confirmed’ alarm. NOTE:
BS8243 specifies a confirm time between 8 and 20 hours. This
also can be used in conjunction with testing an omit signal.
8 – 20 hours