Enforcer V10 Programming Guide
INSTALL ZEMS
The Enforcer supports up to 66 inputs. Zone Expander Modules (ZEMS) can be used to expand the Enforcer to have
a further 32 wireless inputs, 32 wired inputs or a combination of both. There are also 2 inputs that can be used on
an I/O Board if connected (refer to installation manual).
ZEM Address
[0] ZEM Address 0 (Inputs 35-42)
[2] ZEM Address 2 (Inputs 51-58)
[1] ZEM Address 1 (Inputs 43-50)
[3] ZEM Address 3 (Inputs 59-66)
Please note: Inputs 33 and 34 are taken from the I/O board, these do not need to be addressed.
ZEM Installed
[0] No
[2] EURO-ZEM32-WE
[1] ZEM8/EURO37R
Enter Location
The text entered here will be displayed on the LCD display if a fault occurs on the ZEM, so the ZEM can be easily
located or referenced. For example, the location text maybe “ZEM Kitchen”, “ZEM Loft” etc.
Install ZEMS Programming
1.
Press
or
to scroll to ‘INSTALL ZEMS’. Press
.
2.
Press
[
or
]
to select the ‘ZEM Address’ . Press
.
3.
Press
[
or
]
to select the ‘ZEM8 or ZEM32-WE’ or No’ to ‘ZEM Installed’.
Press
.
4.
Enter the location of the ZEM. This is so it is referenced and will appear on the
display if a fault occurs. Press
to return to ZEM addressing.
5.
Press
to return to the Engineers menu.
CHANGE OUTPUTS
This function programs all output types, Any output type may be programmed to any of the systems outputs,
including any outputs for wireless bells. Outputs must be used within their rated capacity. Please see the installation
manual.
Common output types
Refer to Appendix D, for all output type options. Most commonly used input types are:
[0003] Intruder Any
[0018] Unconfirmed Any
[0006] Confirmed Any
[0051] Line Fault
[0014] Siren Any
[0052] Mains Fail
[0016] Strobe Any
[1###] Follow Input