3.3
Wiring
After the cable is brought through the backbox (conduit hole) and connected to the reader the hole
must be sealed with RTV silicone to weatherproof the reader.
Note:
We recommend the use of liquid tight conduit and fittings. RTV silicone can also be used an
alternative.
Terminal Description
Terminal Description
Terminal Description
P1-1
Beeper Input
(BEEP)
P2-1
GPIO4 (RS485-Y / TXA)
P3-1
Functional Earth Ground
(symbol)
P1-2
LED Input
(GRN)
P2-2
GPIO3 (RS485-Z / TXB)
P3-2
Normally Closed (NC) - Relay 1
P1-3
Ground
(GND)
P2-3
**Wiegand Data 0 / Data
(DATA0/DATA)
P3-3
Common (COM) - Relay 1
P1-4
+VDC
P2-4
**Wiegand Data 1 / Clock
(DATA1/CLK)
P3-4
Normally Open (NO) - Relay 1
P1-5
Unused
(DRAIN)
P2-5
*Open Collector Output /
Tamper (OC/TMPR)
P3-5
Normally Closed (NC) - Relay 2
P1-6
LED Input
(RED)
P2-6
GPIO2 (RS232-R / RS485-RXB) P3-6
Common (COM) - Relay 2
P1-7
Hold Input
(HOLD)
P2-7
GPIO1 (RS232-T / RS485-RXA)
P3-7
Normally Open (NO) - Relay 2
*
Tamper Output - When activated, output synchronizes to ground (default).
**
Dependent upon reader configuration. See the HTOG for Wiegand and
Clock-in-Data configurations.
OSDP:
GPIO1 and GPIO2 are RE-485 lines that carry OSDP messages.
GPIO3 and GPIO4 are an auxiliary input and output respectively, which can be
monitored/controlled via OSDP.
P3-8
Normally Closed (NC) - Relay 3
P3-9
Common (COM) - Relay 3
P3-10
Normally Open (NO) - Relay 3
ATTENTION
Observe precautions for handling