40
NGS Mach II User Guide v1.1
IMPORTANT!
• Always consult the vehicle’s shop manual before beginning any test. Failure to follow these
instructions and those includes in the vehicle’s shop manual may result in serious injury or death.
• Always consult Ford’s TSB 01-6-2 for important information before replacing any PATS related modules.
• Do not remove the module or turn the ignition off (or on) unless instructed to do so.
• Make sure to clear all DTCs before beginning.
Programmable Module Installation
Inhale Data —CAN Vehicles
1. Select the Vehicle, Module, and Action (
PMI-
Programmable Module Installation
)
from
the Main Menu.
1 )MODEL : 2008 CROWN VICTORIA
4.6L
2)MODULE: RCM - RESTRAINT CONTROL M
3)ACTION : PMI-PROGRAMMABLE MODULE
4)GO ->
SELECT ITEM AND PRESS TRIGGER TO START
2. Highlight
GO
and then press
TRIGGER
.
1 )MODEL : 2008 CROWN VICTORIA
4.6L
2)MODULE: RCM - RESTRAINT CONTROL M
3)ACTION : PMI-PROGRAMMABLE MODULE
4)GO ->
SELECT ITEM AND PRESS TRIGGER TO START
3. Select
SERVICE BAY FUNCTIONS
and then
press
TRIGGER
.
SERVICE BAY FUNCTIONS
*RETURN TO MAIN MENU*
SELECT ITEM AND PRESS TRIGGER TO START
4. Reselect the module, press
TRIGGER
and
then highlight
INHALE XXX PMI DATA
and then press
TRIGGER
.
Note: NGS
displays the actual module selected.
INHALE RCM PMI DATA
EXHALE RCM PMI DATA
SELECT ITEM AND PRESS TRIGGER TO START
5. If NGS does not display a
saved data
message
, proceed to step 6.
If there is previously saved data in NGS, the
following screen is displayed:
THERE IS A PREVIOUS
XXX INHALE SAVED
VIN:XXXXXXXXXXXXXXXXX
OK TO OVERWRITE DATA?
PRESS TRIGGER TO OVERWRITE
PRESS CANCEL TO EXIT
Note: NGS displays the actual module
selected and the 17 digit VIN.
• To
overwrite
the data stored in NGS and
retrieve the data from the module press
TRIGGER
and proceed to step 6.
• To
keep
the currently stored data press
CANCEL
to exit the procedure.